TY - JOUR
T1 - Effects of Daily Activities and Position on Kinematics and Contact Mechanics of Dual Mobility Hip Implant
AU - Gao, Yongchang
AU - Zhao, Xin
AU - Chen, Shibin
AU - Zhang, Jing
AU - Chen, Zhenxian
AU - Jin, Zhongmin
N1 - Publisher Copyright:
© 2020 Yongchang Gao et al.
PY - 2020
Y1 - 2020
N2 - Dual mobility hip implants have been widely introduced to overcome dislocation in recent years. However, the potential influence of different gaits on kinematics and contact mechanics for dual mobility hip implants is still unclear. Furthermore, a large range of motion coupling with the implant position, especially high inclination or anteversion angle, may result in poor kinematics and contact mechanics. A previously developed dynamic finite element method was adopted in this study to examine the kinematics and corresponding stability of dual mobility hip implants under different gaits coupling with different inclinations or anteversion angles. The results showed only inner relative sliding under knee-bending for dual mobility hip implants under moderate inclination and anteversion angles, whereas an anteversion angle of 25° induced both impingement and consequent relative sliding of the outer articulation. However, the impingement (between the stem neck and the liner inner rim) indeed happened under stair-climbing and sitting-down/stand-up as well as combined movements when inclination and anteversion angles were set as 45° and 0°, respectively, and this finally led to relative sliding at the outer articulation. A high inclination angle did not worsen both the impingement and related outer sliding compared to modest inclination and anteversion angles of the liner, but a high anteversion angle prolonged the period of both the impingement and the outer relative sliding. The extreme motions and high anteversion angles are hardly inevitable, and they indeed lead to motions at both articulations for dual mobility hip implants.
AB - Dual mobility hip implants have been widely introduced to overcome dislocation in recent years. However, the potential influence of different gaits on kinematics and contact mechanics for dual mobility hip implants is still unclear. Furthermore, a large range of motion coupling with the implant position, especially high inclination or anteversion angle, may result in poor kinematics and contact mechanics. A previously developed dynamic finite element method was adopted in this study to examine the kinematics and corresponding stability of dual mobility hip implants under different gaits coupling with different inclinations or anteversion angles. The results showed only inner relative sliding under knee-bending for dual mobility hip implants under moderate inclination and anteversion angles, whereas an anteversion angle of 25° induced both impingement and consequent relative sliding of the outer articulation. However, the impingement (between the stem neck and the liner inner rim) indeed happened under stair-climbing and sitting-down/stand-up as well as combined movements when inclination and anteversion angles were set as 45° and 0°, respectively, and this finally led to relative sliding at the outer articulation. A high inclination angle did not worsen both the impingement and related outer sliding compared to modest inclination and anteversion angles of the liner, but a high anteversion angle prolonged the period of both the impingement and the outer relative sliding. The extreme motions and high anteversion angles are hardly inevitable, and they indeed lead to motions at both articulations for dual mobility hip implants.
UR - https://www.scopus.com/pages/publications/85082684438
U2 - 10.1155/2020/8103523
DO - 10.1155/2020/8103523
M3 - 文章
C2 - 32257086
AN - SCOPUS:85082684438
SN - 2040-2295
VL - 2020
JO - Journal of Healthcare Engineering
JF - Journal of Healthcare Engineering
M1 - 8103523
ER -