Peak shaving operation of more and more large power steam turbines become necessary due to the load fluctuations. The characteristics of steam distribution system of a steam turbine under part-load conditions will affect not only the economy but also the rotor system stability of the unit. A fluid structure interaction method was used in this paper. The rotor system stability of a subcritical 600 MW steam turbine was studied under part-load conditions where unbalanced fluid force was considered. The mechanism of worsen stability of rotor system after turning to sequence valve mode was analyzed. An optimum mode of steam distribution system was proposed. The mode had been used for some practical turbine units and improved their stability of rotor systems. The research may help to improve the performance of the steam distribution system of a large power steam turbine.