TY - JOUR
T1 - Effect of fin types and Prandtl number on performance of plate-fin heat exchanger
T2 - Experimental and numerical assessment
AU - Yang, Huizhu
AU - Wen, Jian
AU - Wang, Simin
AU - Li, Yanzhong
N1 - Publisher Copyright:
© 2018 Elsevier Ltd
PY - 2018/11/5
Y1 - 2018/11/5
N2 - An experimental investigation is performed using liquid R113 to study the thermohydraulic characteristics of plate-fin heat exchanger with plain, serrated and perforated fins. Meanwhile, three performance evaluation criteria j/f, j/f1/2 and j/f1/3 are used to qualitative compare their comprehensive performance. Further, to study the effects of heating condition and Prandtl number on heat transfer, a numerical model of serrated fins is carried out. The fin channels with a uniform heat flux at bottom end or at both bottom and upper ends are studied as two types of heating conditions, namely, single-fold and two-fold modes. Besides, using air (Pr = 0.744), R113 (Pr = 9.02) and ethylene glycol (Pr = 51.65) aqueous solution as working media, the Prandtl number effect is discussed. The results reveal that the comprehensive performance of serrated fins is the best. Colburn factor j of single-fold mode is lower than that of two-fold mode. The Colburn factor j decreases as the Prandtl number increases in laminar flow and it is independent of Prandtl number in turbulent flow. A modified Colburn factor j based on the Manglik & Bergles correlation is proposed as functions of (Pr/Prair)−0.04827 in laminar flow. The conclusions provide the guidance on the design of plate fin heat exchanger.
AB - An experimental investigation is performed using liquid R113 to study the thermohydraulic characteristics of plate-fin heat exchanger with plain, serrated and perforated fins. Meanwhile, three performance evaluation criteria j/f, j/f1/2 and j/f1/3 are used to qualitative compare their comprehensive performance. Further, to study the effects of heating condition and Prandtl number on heat transfer, a numerical model of serrated fins is carried out. The fin channels with a uniform heat flux at bottom end or at both bottom and upper ends are studied as two types of heating conditions, namely, single-fold and two-fold modes. Besides, using air (Pr = 0.744), R113 (Pr = 9.02) and ethylene glycol (Pr = 51.65) aqueous solution as working media, the Prandtl number effect is discussed. The results reveal that the comprehensive performance of serrated fins is the best. Colburn factor j of single-fold mode is lower than that of two-fold mode. The Colburn factor j decreases as the Prandtl number increases in laminar flow and it is independent of Prandtl number in turbulent flow. A modified Colburn factor j based on the Manglik & Bergles correlation is proposed as functions of (Pr/Prair)−0.04827 in laminar flow. The conclusions provide the guidance on the design of plate fin heat exchanger.
KW - Experimental study
KW - Fin geometries
KW - Fold mode
KW - Plate-fin heat exchanger
KW - Prandtl number
UR - https://www.scopus.com/pages/publications/85052656358
U2 - 10.1016/j.applthermaleng.2018.08.063
DO - 10.1016/j.applthermaleng.2018.08.063
M3 - 文章
AN - SCOPUS:85052656358
SN - 1359-4311
VL - 144
SP - 726
EP - 735
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering