T1 - Effect of duct aspect ratio on heat transfer and friction in steam-cooled ducts with 60° angled rib turbulators
AU - Shui, Linqi
AU - Gao, Jianmin
AU - Shi, Xiaojun
AU - Liu, Jiazeng
PY - 2013/9
Y1 - 2013/9
N2 - The effect of duct aspect ratio on heat transfer and friction characteristics is investigated experimentally and numerically. Heat transfer experiments as well as pressure drop measurements are carried out to get detailed local heat transfer coefficient distributions and friction factor data for steam-cooled ducts with 60° angled ribs. The test cases are also analyzed numerically by adopting the SSG turbulence model. Four different duct aspect ratios (AR) are studied: AR. = 1/4, 1/2, 1/1 and 2/1, the corresponding hydraulic diameter (D) is 32.0. mm, 53.33. mm, 40.0. mm and 53.33. mm, and the rib height-to-hydraulic diameter ratio (e/. D) is 0.078, 0.047, 0.0475 and 0.047, respectively. The rib pitch-to-rib height ratio (p/. e) is kept 10 for all the ducts. The investigated Re number ranges from 10,000 to 80,000. Both the experimental and numerical results show the similar trend on heat transfer and friction loss, but the prediction values are higher by 3-15% and 2-20%, respectively. The centerline heat transfer coefficient of steam on the ribbed side wall is gradually increased in the fully developed flow region because of the rib angle. The overall heat transfer coefficient is increased with increasing duct aspect ratio (except the duct of AR. = 1/1). The averaged heat transfer coefficient ratio of steam is higher by 12-25% than air at the same test conditions. The highest heat transfer enhancement accompanied by the highest friction factor is occurred at AR. = 2/1, however, the optimum thermal enhancement factor is found at AR. = 1/2.
AB - The effect of duct aspect ratio on heat transfer and friction characteristics is investigated experimentally and numerically. Heat transfer experiments as well as pressure drop measurements are carried out to get detailed local heat transfer coefficient distributions and friction factor data for steam-cooled ducts with 60° angled ribs. The test cases are also analyzed numerically by adopting the SSG turbulence model. Four different duct aspect ratios (AR) are studied: AR. = 1/4, 1/2, 1/1 and 2/1, the corresponding hydraulic diameter (D) is 32.0. mm, 53.33. mm, 40.0. mm and 53.33. mm, and the rib height-to-hydraulic diameter ratio (e/. D) is 0.078, 0.047, 0.0475 and 0.047, respectively. The rib pitch-to-rib height ratio (p/. e) is kept 10 for all the ducts. The investigated Re number ranges from 10,000 to 80,000. Both the experimental and numerical results show the similar trend on heat transfer and friction loss, but the prediction values are higher by 3-15% and 2-20%, respectively. The centerline heat transfer coefficient of steam on the ribbed side wall is gradually increased in the fully developed flow region because of the rib angle. The overall heat transfer coefficient is increased with increasing duct aspect ratio (except the duct of AR. = 1/1). The averaged heat transfer coefficient ratio of steam is higher by 12-25% than air at the same test conditions. The highest heat transfer enhancement accompanied by the highest friction factor is occurred at AR. = 2/1, however, the optimum thermal enhancement factor is found at AR. = 1/2.
KW - Experiment
KW - Heat transfer enhancement
KW - Numerical simulation
KW - Ribbed duct
KW - Steam-cooling
UR - https://www.scopus.com/pages/publications/84878919479
U2 - 10.1016/j.expthermflusci.2013.04.010
DO - 10.1016/j.expthermflusci.2013.04.010
M3 - 文章
AN - SCOPUS:84878919479
SN - 0894-1777
VL - 49
SP - 123
EP - 134
JO - Experimental Thermal and Fluid Science
JF - Experimental Thermal and Fluid Science
ER -