跳到主要导航 跳到搜索 跳到主要内容

Effect of adaptive statistical iterative reconstruction-V algorithm and deep learning image reconstruction algorithm on image quality and emphysema quantification in COPD patients under ultra-low-dose conditions

  • Guangming Ma
  • , Yuequn Dou
  • , Shan Dang
  • , Nan Yu
  • , Yanbing Guo
  • , Dong Han
  • , Chenwang Jin
  • The First Affiliated Hospital of Xi’an Jiaotong University
  • Shaanxi University of Chinese Medicine

科研成果: 期刊稿件文章同行评审

5 引用 (Scopus)

摘要

Purpose: To explore the effect of different reconstruction algorithms (ASIR-V and DLIR) on image quality and emphysema quantification in chronic obstructive pulmonary disease (COPD) patients under ultra-low-dose scanning conditions. Materials and Methods: This prospective study with patient consent included 62 COPD patients. Patients were examined by pulmonary function test (PFT), standard-dose CT (SDCT) and ultra-low-dose CT (ULDCT). SDCT images were reconstructed with filtered-back-projection (FBP), while ULDCT images were reconstructed using FBP, 30%ASIR-V, 60%ASIR-V, 90%ASIR-V, low-strength (DLIR-L), medium-strength (DLIR-M) and high-strength DLIR (DLIR-H) to form 8 image sets. Images were analysed using a commercial computer aided diagnosis (CAD) software. Parameters such as image noise, lung volume (LV), emphysema index (EI), mean lung density (MLD) and 15th percentile of lung density (PD15) were measured. Two radiologists evaluated tracheal and pulmonary artery image quality using a 5-point scale. Measurements were compared and the correlation between EI and PFT indices was analysed. Result: ULDCT used 0.46 ± 0.22 mSv in radiation dose, 93.8% lower than SDCT (P < .001). There was no difference in LV and MLD among image groups (P > .05). ULDCT-ASIR-V90% and ULDCT-DLIR-M had similar image noise and EI and PD15 values to SDCT-FBP, and ULDCT-DLIR-M and ULDCT-DLIR-H had similar subjective scores to SDCT-FBP (all P > .05). ULDCT-DLIR-M provided the best correlation between EI and the FEV1/FVC and FEV1% indices in PFT, and the lowest deviations with SDCT-FBP in both EI and PD15. Conclusion: DLIR-M provides the best image quality and emphysema quantification for COPD patients in ULDCT. Advances in knowledge: Ultra-low-dose CT scanning combined with DLIR-M reconstruction is comparable to standard dose images for quantitative analysis of emphysema and image quality.

源语言英语
页(从-至)535-543
页数9
期刊British Journal of Radiology
98
1168
DOI
出版状态已出版 - 1 4月 2025
已对外发布

学术指纹

探究 'Effect of adaptive statistical iterative reconstruction-V algorithm and deep learning image reconstruction algorithm on image quality and emphysema quantification in COPD patients under ultra-low-dose conditions' 的科研主题。它们共同构成独一无二的学术指纹。

引用此