TY - JOUR
T1 - Economic optimization and thermodynamic analysis of a novel nuclear district cooling system
AU - Liu, Weiqi
AU - Zhao, Quanbin
AU - Sun, Zhiyong
AU - Liu, Xingmin
AU - Li, Gen
AU - Yan, Junjie
AU - Wang, Jinshi
N1 - Publisher Copyright:
© 2024 Elsevier Ltd
PY - 2024/6/15
Y1 - 2024/6/15
N2 - “Yanlong” pool-type low-temperature heating reactor (DHR-400) stands at a highly promising nuclear heating technology. However, its annual utilization duration faces constraints when exclusively employed for winter heating. To cope with this challenge, a novel nuclear district cooling system driven by DHR-400 is proposed for the first time in this paper. As the core component of the proposed nuclear district cooling system, single-effect double-lift LiBr-H2O absorption refrigeration system (SDARS) can significantly increase the temperature difference between the supply and return of the primary heating network (PHN), thereby reducing the transmission energy consumption. Despite the significant potential, the optimization design of SDARS has received limited attention. An optimization model for SDARS with the annual cost (AC) as the objective function is developed. Focusing on a real district cooling scenario in Xi'an High-tech Zone, the heat transfer areas of all process units and the operating parameters of all streams in SDARS are optimized. Results demonstrate that the optimal annual average coefficient of performance (AACOP) is improved by 10.63 % and AC is reduced by 5.44 % compared with the Benchmark case. The dynamic payback period for the combined heating and cooling system driven by DHR-400 is reduced by 5.53 years compared to the heating-only system.
AB - “Yanlong” pool-type low-temperature heating reactor (DHR-400) stands at a highly promising nuclear heating technology. However, its annual utilization duration faces constraints when exclusively employed for winter heating. To cope with this challenge, a novel nuclear district cooling system driven by DHR-400 is proposed for the first time in this paper. As the core component of the proposed nuclear district cooling system, single-effect double-lift LiBr-H2O absorption refrigeration system (SDARS) can significantly increase the temperature difference between the supply and return of the primary heating network (PHN), thereby reducing the transmission energy consumption. Despite the significant potential, the optimization design of SDARS has received limited attention. An optimization model for SDARS with the annual cost (AC) as the objective function is developed. Focusing on a real district cooling scenario in Xi'an High-tech Zone, the heat transfer areas of all process units and the operating parameters of all streams in SDARS are optimized. Results demonstrate that the optimal annual average coefficient of performance (AACOP) is improved by 10.63 % and AC is reduced by 5.44 % compared with the Benchmark case. The dynamic payback period for the combined heating and cooling system driven by DHR-400 is reduced by 5.53 years compared to the heating-only system.
KW - Nuclear district cooling system
KW - Optimal hourly output power
KW - Optimization design
KW - Single-effect double-lift absorption refrigeration system
KW - Thermodynamic modeling
UR - https://www.scopus.com/pages/publications/85189151178
U2 - 10.1016/j.applthermaleng.2024.123042
DO - 10.1016/j.applthermaleng.2024.123042
M3 - 文章
AN - SCOPUS:85189151178
SN - 1359-4311
VL - 247
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
M1 - 123042
ER -