T1 - Direct electrochemistry of glucose oxidase and biosensing for glucose based on boron-doped carbon nanotubes modified electrode
AU - Deng, Chunyan
AU - Chen, Jinhua
AU - Chen, Xiaoli
AU - Xiao, Chunhui
AU - Nie, Lihua
AU - Yao, Shouzhuo
PY - 2008/3/14
Y1 - 2008/3/14
N2 - Due to their unique physicochemical properties, doped carbon nanotubes are now extremely attractive and important nanomaterials in bioanalytical applications. In this work, selecting glucose oxidase (GOD) as a model enzyme, we investigated the direct electrochemistry of GOD based on the B-doped carbon nanotubes/glassy carbon (BCNTs/GC) electrode with cyclic voltammetry. A pair of well-defined, quasi-reversible redox peaks of the immobilized GOD was observed at the BCNTs based enzyme electrode in 0.1 M phosphate buffer solution (pH 6.98) by direct electron transfer between the protein and the electrode. As a new platform in glucose analysis, the new glucose biosensor based on the BCNTs/GC electrode has a sensitivity of 111.57 μA mM-1 cm-2, a linear range from 0.05 to 0.3 mM and a detection limit of 0.01 mM (S/N = 3). Furthermore, the BCNTs modified electrode exhibits good stability and excellent anti-interferent ability to the commonly co-existed uric acid and ascorbic acid. These indicate that boron-doped carbon nanotubes are the good candidate material for the direct electrochemistry of the redox-active enzyme and the construction of the related enzyme biosensors.
AB - Due to their unique physicochemical properties, doped carbon nanotubes are now extremely attractive and important nanomaterials in bioanalytical applications. In this work, selecting glucose oxidase (GOD) as a model enzyme, we investigated the direct electrochemistry of GOD based on the B-doped carbon nanotubes/glassy carbon (BCNTs/GC) electrode with cyclic voltammetry. A pair of well-defined, quasi-reversible redox peaks of the immobilized GOD was observed at the BCNTs based enzyme electrode in 0.1 M phosphate buffer solution (pH 6.98) by direct electron transfer between the protein and the electrode. As a new platform in glucose analysis, the new glucose biosensor based on the BCNTs/GC electrode has a sensitivity of 111.57 μA mM-1 cm-2, a linear range from 0.05 to 0.3 mM and a detection limit of 0.01 mM (S/N = 3). Furthermore, the BCNTs modified electrode exhibits good stability and excellent anti-interferent ability to the commonly co-existed uric acid and ascorbic acid. These indicate that boron-doped carbon nanotubes are the good candidate material for the direct electrochemistry of the redox-active enzyme and the construction of the related enzyme biosensors.
KW - Boron-doped carbon nanotubes (BCNTs)
KW - Direct electrochemistry
KW - Glucose
KW - Glucose oxidase
UR - https://www.scopus.com/pages/publications/39649091200
U2 - 10.1016/j.bios.2007.11.009
DO - 10.1016/j.bios.2007.11.009
M3 - 文章
C2 - 18178424
AN - SCOPUS:39649091200
SN - 0956-5663
VL - 23
SP - 1272
EP - 1277
JO - Biosensors and Bioelectronics
JF - Biosensors and Bioelectronics
IS - 8
ER -