跳到主要导航 跳到搜索 跳到主要内容

Development of a reflective optical encoder with submicron accuracy

科研成果: 期刊稿件文章同行评审

34 引用 (Scopus)

摘要

Signal distortion is a key issue that limits the measurement resolution and accuracy of optical encoders. In this paper, an optical encoder based on generalized grating imaging using a two-dimensional index grating is presented. The general expression of intensity distribution for generalized grating imaging including the relative displacement between the scale grating and the reading head is derived, and the formation of the signal distortion of the optical encoder is analyzed. Then, a two-dimensional index grating, which consists of multiple grating tracks with defined offsets, is proposed to suppress the dominant third and fifth order harmonic signals. The operating principle of the two-dimensional index grating is explained in detail and a reflective optical encoder is developed. In the experiment, approximately ideal Lissajous figure of the encoder signals is obtained. Fourier analysis of the encoder signals shows that both the third and fifth order harmonic distortions are below 0.6%. Experimental results show that the interpolation error of the optical encoder is within ±0.18μm, and the accuracy is better than ±0.3μm over 255 mm travel range with a maximum variation of 0.136 μm.

源语言英语
页(从-至)126-132
页数7
期刊Optics Communications
411
DOI
出版状态已出版 - 15 3月 2018

学术指纹

探究 'Development of a reflective optical encoder with submicron accuracy' 的科研主题。它们共同构成独一无二的指纹。

引用此