跳到主要导航 跳到搜索 跳到主要内容

Development and Application of Ex-Vessel Neutron Dosimetry System on Tianwan VVER-1000 Unit 2

  • Meng Zhang
  • , Chunfeng Shi
  • , Yaping Zhang
  • , Liangzhi Cao
  • , Donghui Wang
  • Ltd.
  • School of Nuclear Science and Technology
  • Xi'an Jiaotong University
  • State Nuclear Power Plant Service Company

科研成果: 书/报告/会议事项章节 › 会议稿件 › 同行评审

摘要

Ex-Vessel Neutron Dosimetry (EVND) systems had been used worldwide in nuclear power industry because of its easier implementation, higher reliability and lower cost compared to in-vessel surveillance capsules. EVND system measures reactor pressure vessel (RPV) neutron fluence and neutron spectrum with multiple activation foils installed outside of RPV. A special EVND system was designed and manufactured for Tianwan Nuclear Power Plant VVER-1000 reactor units in China, based on the characters of their fuel scheme, reactor internals, RPV and also the components and structures outside of RPV. The EVND system was composed of six dosimeter sets which were installed in six different locations. Each dosimeter set had eight foils. Stainless steel chain which was used to support the dosimeter sets also provided useful information to describe the axial distribution of reactor neutron fluence. The system was installed during the 11th refueling outage and was with-drawn after one fuel cycle. Then the activated foils were measured and analyzed to obtain the reaction rates of target nuclides. Neutron transport calculation was carried out to obtain neutron fluence and neutron spectrum distribution. Spectrum adjust-ment calculation was carried out to obtain best estimated neutron fluence based on dosimeter measurement results. Calculated, best estimated and measured reaction rates were compared for each foil. Also, calculated and best estimated neutron spec-trums at each dosimeter set location were compared. Finally, correctness of RPV fast neutron fluence and spectrum was assessed based on these comparisons. The results showed that the calculated, measured and best estimated reaction rates of most dosimeters complied with each other very well. It can be concluded that the EVND system can provide accurate RPV neutron fluence for Tianwan VVER-1000 reactor units.

源语言英语
主期刊名Proceedings of the 32nd International Conference on Nuclear Engineering—Volume 1; ICONE 2025
编辑Sichao Tan, Weiqiang Xu, Yanyan Zhu
出版商Springer Science and Business Media Deutschland GmbH
页171-182
页数12
ISBN(印刷版)9789819527939
DOI
出版状态已出版 - 2026
活动32nd International Conference on Nuclear Engineering, ICONE 2025 - Weihai, 中国
期限: 22 6月 2025 → 26 6月 2025

丛书

姓名Springer Proceedings in Physics
卷330 SPPHY
ISSN(印刷版)0930-8989
ISSN(电子版)1867-4941

会议

会议32nd International Conference on Nuclear Engineering, ICONE 2025
国家/地区中国
市Weihai
时期22/06/25 → 26/06/25

学术指纹

探究 'Development and Application of Ex-Vessel Neutron Dosimetry System on Tianwan VVER-1000 Unit 2' 的科研主题。它们共同构成独一无二的学术指纹。

引用此