跳到主要导航 跳到搜索 跳到主要内容

Determination of ranolazine in rat plasma by liquid chromatography- electrospray ionization mass spectrometry

  • J. Zhong
  • , X. Q. Liu
  • , Y. Chen
  • , X. P. Zhao
  • , Y. S. Wang
  • , G. J. Wang
  • China Pharmaceutical University

科研成果: 期刊稿件文章同行评审

15 引用 (Scopus)

摘要

A rapid and sensitive liquid chromatographic-mass spectrometric (LC-MS) method, with phenoprolamine hydrochloride (DDPH) as internal standard, has been developed and validated for determination of ranolazine in rat plasma. After liquid-liquid extraction the compound was analyzed by HPLC on a C18 column, with methanol-10 mM ammonium acetate, 76:24 (v/v), as mobile phase, coupled with electrospray ionization mass spectrometry (ESI-MS). The protonated analyte was quantified by selected-ion monitoring (SIM) with a quadrupole mass spectrometer in positive-ion mode. Calibration plots were linear over the concentration range 0.046-12 μg mL-1. Inter and intra-day precision (CV%) and accuracy (RE%) for quality-control samples (0.187, 1.5, and 12 μg mL-1) ranged between 2.96 and 13.38% and between -11.23 and 12.67%, respectively. Extraction recovery of RAN from plasma was in the range 82.77-86.54%. The method enables rapid, sensitive, precise, and accurate measurement of the concentration of ranolazine in rat plasma.

源语言英语
页(从-至)123-127
页数5
期刊Chromatographia
63
3-4
DOI
出版状态已出版 - 2月 2006