T1 - Design of a prosthesis socket with pressure-adjustable interface
AU - Gan, Yun
AU - Li, Xiang
AU - Sang, Yuanjun
AU - Daniel, S. U.
AU - Luo, Yun
PY - 2013/6/5
Y1 - 2013/6/5
N2 - A functional prosthesis socket should be safely wearable and be able to transfer force or movement between weight-bearing stump and prosthesis. This requires the man-machine interface in the socket to be both flexible and stiffer, which is apparently contradictory in its design. To solve this problem, a new design concept to apply the clamping pressure on stump only in needs is proposed, so the stump soft tissue can avoid longtime overload. To realize this concept, a pressure-adjustable chamber with negative stiffness is designed to form pressure units in sockets. The feasibility of the chamber in meeting the rapid switching the interface's mechanical property from soft to hard is theoretically studied. Negative stiffness of these pressure units makes it easier to adjust the tightness of soft tissue compression, which means the driving force needed can be lower and the actuator can be smaller, and provides the socket with the property of overload protection. A physical model of prosthesis socket with four pressure-adjustable chambers is fabricated for the experimental confirmation of the conceptual design. Promising results are obtained both in its pressure-adjustability and response speed. The new design can help prosthesis socket gain high function transitivity and comfort.
AB - A functional prosthesis socket should be safely wearable and be able to transfer force or movement between weight-bearing stump and prosthesis. This requires the man-machine interface in the socket to be both flexible and stiffer, which is apparently contradictory in its design. To solve this problem, a new design concept to apply the clamping pressure on stump only in needs is proposed, so the stump soft tissue can avoid longtime overload. To realize this concept, a pressure-adjustable chamber with negative stiffness is designed to form pressure units in sockets. The feasibility of the chamber in meeting the rapid switching the interface's mechanical property from soft to hard is theoretically studied. Negative stiffness of these pressure units makes it easier to adjust the tightness of soft tissue compression, which means the driving force needed can be lower and the actuator can be smaller, and provides the socket with the property of overload protection. A physical model of prosthesis socket with four pressure-adjustable chambers is fabricated for the experimental confirmation of the conceptual design. Promising results are obtained both in its pressure-adjustability and response speed. The new design can help prosthesis socket gain high function transitivity and comfort.
KW - Human-machine interface
KW - Negative stiffness
KW - Pressure-adjustability
KW - Prosthesis socket
UR - https://www.scopus.com/pages/publications/84879726632
U2 - 10.3901/JME.2013.11.106
DO - 10.3901/JME.2013.11.106
M3 - 文章
AN - SCOPUS:84879726632
SN - 0577-6686
VL - 49
SP - 106
EP - 113
JO - Jixie Gongcheng Xuebao/Chinese Journal of Mechanical Engineering
JF - Jixie Gongcheng Xuebao/Chinese Journal of Mechanical Engineering
IS - 11
ER -