TY - JOUR
T1 - Design analysis of DRAGON-IV LiPb loop
AU - Zhu, Zhiqiang
AU - Huang, Qunying
AU - Gao, Sheng
AU - Song, Yong
AU - Li, Chunjing
AU - Peng, Lei
AU - Chen, Hongli
AU - Liu, Songlin
AU - Ling, Xinzhen
AU - Chen, Yaping
AU - Chen, Yunlong
AU - Wu, Yican
PY - 2011/10
Y1 - 2011/10
N2 - Based on the experience of the thermal convection LiPb loops, a multi-functional forced convection loop, DRAGON-IV, was constructed to confirm the different design functions of blankets in China. It can provide directly the valuable and real working condition, such as high magnetic field, flowing liquid LiPb with high temperature, tensile stress, reference TBM mockup, etc. Therefore, many out-of-pile experiments can be performed in it, such as high temperature corrosion experiment, stress corrosion, MHD effect under magnetic field for different manifolds, characteristic of flowing and heat transfer for mini-TBM, and purification technology. The detailed information of DRAGON-IV is described in the paper, its design objective, experimental parameters, main components are introduced, and the design scheme and analysis results of thermal-hydraulic for some key subsystems are presented. The results showed that they meet well the design requirement.
AB - Based on the experience of the thermal convection LiPb loops, a multi-functional forced convection loop, DRAGON-IV, was constructed to confirm the different design functions of blankets in China. It can provide directly the valuable and real working condition, such as high magnetic field, flowing liquid LiPb with high temperature, tensile stress, reference TBM mockup, etc. Therefore, many out-of-pile experiments can be performed in it, such as high temperature corrosion experiment, stress corrosion, MHD effect under magnetic field for different manifolds, characteristic of flowing and heat transfer for mini-TBM, and purification technology. The detailed information of DRAGON-IV is described in the paper, its design objective, experimental parameters, main components are introduced, and the design scheme and analysis results of thermal-hydraulic for some key subsystems are presented. The results showed that they meet well the design requirement.
KW - Design analysis
KW - DRAGON-IV
KW - LiPb loop
UR - https://www.scopus.com/pages/publications/80054021899
U2 - 10.1016/j.fusengdes.2011.03.083
DO - 10.1016/j.fusengdes.2011.03.083
M3 - 文章
AN - SCOPUS:80054021899
SN - 0920-3796
VL - 86
SP - 2666
EP - 2669
JO - Fusion Engineering and Design
JF - Fusion Engineering and Design
IS - 9-11
ER -