Deformation of press-fitted metallic resurfacing cups. Part 1: Experimental simulation

  • Z. M. Jin
  • , S. Meakins
  • , M. M. Morlock
  • , P. Parsons
  • , C. Hardaker
  • , M. Flett
  • , G. Isaac
  • University of Leeds
  • Johnson & Johnson
  • Hamburg University of Technology

科研成果: 期刊稿件 › 文章 › 同行评审

103 引用 (Scopus)

摘要

The interference press fit of a metallic one-piece acetabular cup employed for metal-on-metal hip resurfacing procedures was investigated experimentally under laboratory conditions in the present study, in particular regarding the cup deformation. Tests were carried out in cadavers as well as polyurethane foams of various grades with different elastic moduli to represent different cancellous bone qualities. The cadaver test was used to establish the most suitable configuration of the foam model representing realistic support and geometrical conditions at the pelvis. It was found that a spherical cavity, with two identical areas relieved on opposite sides, was capable of creating a two-point pinching action of the ischeal and ilial columns on the cup as the worst-case scenario. Furthermore, the cup deformation produced from such a two-point loading model with a grade 30 foam was similar to that measured from the cadaver test. Therefore, such a protocol was employed in subsequent experimental tests. For a given size of the outside diameter of the cup of 60 mm., the cup deflection was shown to be dependent largely on the cup wall thickness and the diametral interference between cup and prepared cavity at implantation. For a relatively thin cup with a wall thickness between 2.3 mm (equator) and 4 mm (pole) and with a modest nominal diametral interference of 1 mm, which corresponds to an actual interference of approximately 0.5 mm, the maximum diametral cup deflection (at the rim) was around 60 μm, compared with a diametral clearance of 80-120 μm between the femoral head and the acetabular cup, generally required for fluid-film lubrication and tribological performances. Stiffening of the cup, by both thickening and lateralizing by 1 mm, reduced the cup deformation to between 30 and 50 μm with actual diametral interferences between 0.5 and 1 mm.

源语言英语
页(从-至)299-309
页数11
期刊Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
卷220
期2
DOI
出版状态已出版 - 2006
已对外发布是

学术指纹

探究 'Deformation of press-fitted metallic resurfacing cups. Part 1: Experimental simulation' 的科研主题。它们共同构成独一无二的学术指纹。

引用此