Cycle cut-off criterion effect on the performance of cascaded, sensible, combined sensible-latent heat storage tank for concentrating solar power plants

科研成果: 期刊稿件文章同行评审

23 引用 (Scopus)

摘要

Thermocline thermal energy storage (TES) technology that uses the molten salt as heat transfer fluid is cheaper than a traditional two-tank structure, owing to its composite design and use of inexpensive filler materials. Nevertheless, this TES type suffers from the significant disadvantage of low capacity and utilization ratio when it is integrated with concentrating solar power plants due to moderate charge/discharge cut-off values. The primary purpose of the current research is to investigate and evaluate the impact of the change charge/discharge cut-off values on the thermal performance of six different TES tank configurations. First, the equations for the dispersion-concentric model were approached through the MATLAB program, and then the present research results are authenticated. The results show that the thermocline zones shrink when the charge cut-off value rises, and the discharge cut-off value reduces because a higher charge cut-off value and a smaller discharge cut-off value permit a longer charge/discharge time. Moreover, when the cut-off value of the charge/discharge changes simultaneously, the combined sensible-latent heat storage configuration has the highest capacity ratio, utilization ratio, recovered energy, and overall efficiency, which equals 90.55%, 83.3%, 147.2 MWh, 91.3%, respectively, at low charge cut-off value.

源语言英语
文章编号120771
期刊Energy
230
DOI
出版状态已出版 - 1 9月 2021

联合国可持续发展目标

此成果有助于实现下列可持续发展目标:

  1. 可持续发展目标 7 - 经济适用的清洁能源
    可持续发展目标 7 经济适用的清洁能源

学术指纹

探究 'Cycle cut-off criterion effect on the performance of cascaded, sensible, combined sensible-latent heat storage tank for concentrating solar power plants' 的科研主题。它们共同构成独一无二的指纹。

引用此