跳到主要导航 跳到搜索 跳到主要内容

Count Rate Analysis of the Source-range Detector for M310

  • Xi'an Jiaotong University
  • Ltd

科研成果: 期刊稿件会议文章同行评审

摘要

This paper analyses the count rate of the ex-core source-range detector for Unit 4, M310 Pressurized Water Reactor (PWR), at Fujian Fuqing Nuclear Power Co., Ltd (FQNPC). The analysis encompasses power states during Cycle 1 startup and Cycle 3 fuel unloading. The analytical process involves analysing the count rate of the source-range detector, simulating secondary neutron source intensity and calculating nuclide information and neutron source intensity of irradiated fuel assemblies, etc. The maximum error between the theoretically calculated and measured count rate of the source-range detector is found to be 8.318%, which confirms the accuracy and validity of the count rate analysis method applied to the ex-core source-range detector for M310.

源语言英语
期刊论文编号14001
期刊EPJ Web of Conferences
302
DOI
出版状态已出版 - 15 10月 2024
活动2024 Joint International Conference on Supercomputing in Nuclear Applications + Monte Carlo, SNA + MC 2024 - Paris, 法国
期限: 20 10月 202424 10月 2024

学术指纹

探究 'Count Rate Analysis of the Source-range Detector for M310' 的科研主题。它们共同构成独一无二的学术指纹。

引用此