跳到主要导航 跳到搜索 跳到主要内容

Contrast-based transient flow vector distribution in arterial stenosis based on plane wave bubble wavelet imaging and modified optical flow method

  • DIya Wang
  • , Bowen Jing
  • , Jinjin Wan
  • , Yingjie Jia
  • , Yu Zhang
  • , Mingxi Wan
  • Xi'an Jiaotong University

科研成果: 书/报告/会议事项章节 › 会议稿件 › 同行评审

摘要

The objective of this study was to accurately obtain the transient flow vector distribution (FVD) of microbubbles in arterial stenosis by modified optical flow method based on ultrasound contrast plane wave imaging (UCPI). First, a bolus injection experiment was performed in an arterial stenosis flow phantom using inverted plane waves at 400Hz frame rate controlled by Sonix-Touch. The contrast-to-tissue ratio (CTR) of UCPI images and detection sensitivity of microbubbles was then improved by pulse inversion bubble wavelet imaging (PIWI) technique based on a pair of inverted bubble wavelet constructed according to the modified Herring equation. Next, transient displacement and FVD of microbubbles among a set of UCPI images with high CTR and sensitivity were obtained by a modified optical flow method, which added a discontinuity preserving spatio-temporal smoothness constraint, to accurately mark and evaluate the hemodynamic feature in the stenosis. Finally, FVD of microbubbles in the arterial stenosis was depicted clearly by PIWI-based UCPI. Compared to those obtained using pulse inversion harmonic imaging, CTR of UCPI in the stenosis and detection sensitivity of microbubbles near arterial wall were improved by up to 10.09 ± 2.96 dB and 12.52 ± 2.10 dB, respectively. Axial microbubble velocity in the stenosis was 28.45 ± 3.05 mm/s; it was in accordance with the set value. Moreover, compared with results obtained by the conventional optical flow method, an anticlockwise vortex of microbubbles in the distal was described more accurately by the transient FVD obtained using the modified optical flow method. It indicated that contrast-based transient FVD in the arterial stenosis can be acquired accurately by PIWI-based UCPI combined with modified optical flow method.

源语言英语
主期刊名2015 IEEE International Ultrasonics Symposium, IUS 2015
出版商Institute of Electrical and Electronics Engineers Inc.
ISBN(电子版)9781479981823
DOI
出版状态已出版 - 13 11月 2015
活动IEEE International Ultrasonics Symposium, IUS 2015 - Taipei, 中国台湾
期限: 21 10月 2015 → 24 10月 2015

丛书

姓名2015 IEEE International Ultrasonics Symposium, IUS 2015

会议

会议IEEE International Ultrasonics Symposium, IUS 2015
国家/地区中国台湾
市Taipei
时期21/10/15 → 24/10/15

学术指纹

探究 'Contrast-based transient flow vector distribution in arterial stenosis based on plane wave bubble wavelet imaging and modified optical flow method' 的科研主题。它们共同构成独一无二的学术指纹。

引用此