TY - JOUR
T1 - Condensation heat transfer of mixed R134a/R125 outside horizontal tubes
AU - Zhang, Dingcai
AU - Du, Jiadi
AU - Ji, Wentao
AU - Zhang, Zhen
AU - Zhu, Chunjie
AU - He, Yaling
AU - Tao, Wenquan
PY - 2014/5
Y1 - 2014/5
N2 - Experimental studies of film condensation of R134a and mixed R134a/R125 at three different concentrations have been conducted on three tubes, one is smooth tube, the others are two-dimensional and three-dimensional enhanced tubes at the same fin density. The results indicate that the predicted condensation heat transfer coefficients of R134a on smooth tube from Nusselt theory agree with the experimental data within ±10 percent. The condensation heat transfer coefficients of pure R134a are consistent with Nusselt theoretical trend for smooth and enhanced tubes. Compared with pure R134a, the condensation heat transfer coefficients of mixed R134a/R125 are all decreased. For smooth tube, condensation heat transfer coefficient of mixed refrigerants decreased with the increase of temperature difference. But for enhanced tubes, condensation heat transfer coefficients increased with the increase of temperature difference, which is close to pure R134a at high temperature difference, the mixed refrigerant including 6 percent and more R125. Indicating that condensation heat transfer of mixed refrigerants is quite different with pure refrigerants. Condensation heat transfer coefficient of three-dimensional enhanced tube is higher than that of the two-dimensional tubes, and two-dimensional tube is significantly higher than that of smooth tube at the same working fluid. The condensation heat transfer enhancement factor of HT-3D, HT-2D are 9.83 and 7.85, respectively, which compared with smooth tube at the temperature difference 8 K.
AB - Experimental studies of film condensation of R134a and mixed R134a/R125 at three different concentrations have been conducted on three tubes, one is smooth tube, the others are two-dimensional and three-dimensional enhanced tubes at the same fin density. The results indicate that the predicted condensation heat transfer coefficients of R134a on smooth tube from Nusselt theory agree with the experimental data within ±10 percent. The condensation heat transfer coefficients of pure R134a are consistent with Nusselt theoretical trend for smooth and enhanced tubes. Compared with pure R134a, the condensation heat transfer coefficients of mixed R134a/R125 are all decreased. For smooth tube, condensation heat transfer coefficient of mixed refrigerants decreased with the increase of temperature difference. But for enhanced tubes, condensation heat transfer coefficients increased with the increase of temperature difference, which is close to pure R134a at high temperature difference, the mixed refrigerant including 6 percent and more R125. Indicating that condensation heat transfer of mixed refrigerants is quite different with pure refrigerants. Condensation heat transfer coefficient of three-dimensional enhanced tube is higher than that of the two-dimensional tubes, and two-dimensional tube is significantly higher than that of smooth tube at the same working fluid. The condensation heat transfer enhancement factor of HT-3D, HT-2D are 9.83 and 7.85, respectively, which compared with smooth tube at the temperature difference 8 K.
KW - Condensation
KW - Doubly-enhanced tube
KW - Heat transfer
KW - Mixtures
KW - R134a/R125
UR - https://www.scopus.com/pages/publications/84901849038
U2 - 10.3969/j.issn.0438-1157.2014.z1.019
DO - 10.3969/j.issn.0438-1157.2014.z1.019
M3 - 文章
AN - SCOPUS:84901849038
SN - 0438-1157
VL - 65
SP - 119
EP - 124
JO - Huagong Xuebao/Journal of Chemical Industry and Engineering (China)
JF - Huagong Xuebao/Journal of Chemical Industry and Engineering (China)
IS - SUPPL.1
ER -