TY - GEN
T1 - Comparisons of Dynamic Characteristics between Grid-Forming and Grid-Following Converters
AU - Wei, Yunzhuo
AU - Liu, Jia
AU - Xiong, Liangli
AU - Chen, Zhi
AU - Liu, Jinjun
AU - You, Li
AU - Han, Gang
N1 - Publisher Copyright:
© 2024 IEEE.
PY - 2024
Y1 - 2024
N2 - Compared to conventional grid-following (GFL) converters, grid-forming (GFM) converters are considered to provide better voltage and frequency support. Still, rigorous comparisons should be performed to reveal their different behaviors. However, most of the existing research works on comparisons between these two types of converters are focused on stability issues, whereas the pros/cons of both techniques in respect to dynamic characteristics are less studied. In this paper, this topic is fully investigated. Two aspects are considered in this paper, i.e., the transient response to an active/reactive power command from upper-level controller (e.g. an AGC/AVC), and the transient voltage and frequency support effect. The former is evaluated in a single-converter infinite-bus system, whereas the latter is studied in a synthetic down-scale grid system. Small-signal state-space models are deduced to obtain analytical transient responses, which are subsequently verified by simulation results in Matlab/Simulink. The analyses indicate that GFL converters have a fast response to power command, whereas GFM converters provide better transient voltage and frequency support.
AB - Compared to conventional grid-following (GFL) converters, grid-forming (GFM) converters are considered to provide better voltage and frequency support. Still, rigorous comparisons should be performed to reveal their different behaviors. However, most of the existing research works on comparisons between these two types of converters are focused on stability issues, whereas the pros/cons of both techniques in respect to dynamic characteristics are less studied. In this paper, this topic is fully investigated. Two aspects are considered in this paper, i.e., the transient response to an active/reactive power command from upper-level controller (e.g. an AGC/AVC), and the transient voltage and frequency support effect. The former is evaluated in a single-converter infinite-bus system, whereas the latter is studied in a synthetic down-scale grid system. Small-signal state-space models are deduced to obtain analytical transient responses, which are subsequently verified by simulation results in Matlab/Simulink. The analyses indicate that GFL converters have a fast response to power command, whereas GFM converters provide better transient voltage and frequency support.
KW - Dynamic characteristics
KW - Grid-following converter
KW - Grid-forming converter
KW - State-space model
UR - https://www.scopus.com/pages/publications/85199059838
U2 - 10.1109/IPEMC-ECCEAsia60879.2024.10567983
DO - 10.1109/IPEMC-ECCEAsia60879.2024.10567983
M3 - 会议稿件
AN - SCOPUS:85199059838
T3 - 2024 IEEE 10th International Power Electronics and Motion Control Conference, IPEMC 2024 ECCE Asia
SP - 4604
EP - 4610
BT - 2024 IEEE 10th International Power Electronics and Motion Control Conference, IPEMC 2024 ECCE Asia
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 10th IEEE International Power Electronics and Motion Control Conference, IPEMC 2024 ECCE Asia
Y2 - 17 May 2024 through 20 May 2024
ER -