跳到主要导航 跳到搜索 跳到主要内容

Comparison of throttle devices to measure two-phase flowrates of wet gas with extremely-low liquid loading

  • Shanshan Li
  • , Xuebo Zheng
  • , Fan Zhao
  • , Denghui He
  • , Bofeng Bai
  • Xi'an Jiaotong University
  • Xi'an University of Technology

科研成果: 期刊稿件文章同行评审

11 引用 (Scopus)

摘要

The online measurement of wet gas with extremely-low liquid loading (Lockhart-Martinelli parameter lower than 0.02) remains a challenge. In this study, three types of throttle devices, Venturi, orifice plate and cone, are compared experimentally with air-water two-phase flow in a horizontal pipe of inner diameter of 50 mm. High-precision correlations are established to measure the gas and liquid flowrates via a single throttle device. Results show that the two-phase mass flow coefficient (K) of the three throttle devices all increase linearly with the liquid densiometric Froude number and the K correlations are established respectively to correct the gas mass flowrate deviation. The pressure loss ratio (δ) for Venturi is sensitive and monotonous to the liquid loading, which contributes to the high accuracy of liquid flowrate measurement. By incorporating the K correlations, both the gas and liquid mass flowrates can be predicted precisely. The relative error of the gas mass flowrate predicted by the Venturi is within ±2.0% at 95% confidence level, and that of the liquid mass flowrate is within ±15% at 90% confidence level.

源语言英语
文章编号101840
期刊Flow Measurement and Instrumentation
76
DOI
出版状态已出版 - 12月 2020

学术指纹

探究 'Comparison of throttle devices to measure two-phase flowrates of wet gas with extremely-low liquid loading' 的科研主题。它们共同构成独一无二的指纹。