TY - JOUR
T1 - Comparison of throttle devices to measure two-phase flowrates of wet gas with extremely-low liquid loading
AU - Li, Shanshan
AU - Zheng, Xuebo
AU - Zhao, Fan
AU - He, Denghui
AU - Bai, Bofeng
N1 - Publisher Copyright:
© 2020 Elsevier Ltd
PY - 2020/12
Y1 - 2020/12
N2 - The online measurement of wet gas with extremely-low liquid loading (Lockhart-Martinelli parameter lower than 0.02) remains a challenge. In this study, three types of throttle devices, Venturi, orifice plate and cone, are compared experimentally with air-water two-phase flow in a horizontal pipe of inner diameter of 50 mm. High-precision correlations are established to measure the gas and liquid flowrates via a single throttle device. Results show that the two-phase mass flow coefficient (K) of the three throttle devices all increase linearly with the liquid densiometric Froude number and the K correlations are established respectively to correct the gas mass flowrate deviation. The pressure loss ratio (δ) for Venturi is sensitive and monotonous to the liquid loading, which contributes to the high accuracy of liquid flowrate measurement. By incorporating the K correlations, both the gas and liquid mass flowrates can be predicted precisely. The relative error of the gas mass flowrate predicted by the Venturi is within ±2.0% at 95% confidence level, and that of the liquid mass flowrate is within ±15% at 90% confidence level.
AB - The online measurement of wet gas with extremely-low liquid loading (Lockhart-Martinelli parameter lower than 0.02) remains a challenge. In this study, three types of throttle devices, Venturi, orifice plate and cone, are compared experimentally with air-water two-phase flow in a horizontal pipe of inner diameter of 50 mm. High-precision correlations are established to measure the gas and liquid flowrates via a single throttle device. Results show that the two-phase mass flow coefficient (K) of the three throttle devices all increase linearly with the liquid densiometric Froude number and the K correlations are established respectively to correct the gas mass flowrate deviation. The pressure loss ratio (δ) for Venturi is sensitive and monotonous to the liquid loading, which contributes to the high accuracy of liquid flowrate measurement. By incorporating the K correlations, both the gas and liquid mass flowrates can be predicted precisely. The relative error of the gas mass flowrate predicted by the Venturi is within ±2.0% at 95% confidence level, and that of the liquid mass flowrate is within ±15% at 90% confidence level.
KW - Extremely-low liquid loading
KW - Flowrate measurement
KW - Pressure loss ratio
KW - Throttle device
KW - Two-phase mass flow coefficient
KW - Wet gas
UR - https://www.scopus.com/pages/publications/85094179232
U2 - 10.1016/j.flowmeasinst.2020.101840
DO - 10.1016/j.flowmeasinst.2020.101840
M3 - 文章
AN - SCOPUS:85094179232
SN - 0955-5986
VL - 76
JO - Flow Measurement and Instrumentation
JF - Flow Measurement and Instrumentation
M1 - 101840
ER -