跳到主要导航 跳到搜索 跳到主要内容

Comparison of O-ICR wall conditionings for limiter configuration in HT-7 and divertor one in EAST

  • J. S. Hu
  • , J. G. Li
  • , Y. P. Zhao
  • CAS - Institute of Plasma Physics

科研成果: 期刊稿件文章同行评审

5 引用 (Scopus)

摘要

Ion cyclotron resonance discharge-associated oxidation (He/O-ICR) wall conditioning was successfully carried out on full metallic material walls for a divertor configuration in EAST. Within a range of He/O-ICR parameters (5-20 kW, 1.2-7 × 10-2 Pa) in EAST, the highest removal rates (7.8 × 1022 H-atoms/h, 4.2 × 1022 C-atoms/h) were obtained with 20 kW and 7 × 10-2 Pa He/O-ICR. These rates are about 10 times higher than those in HT-7. Oxygen retention rates were lower than HT-7 by a factor of >10. Results of O-ICR cleanings in both EAST and HT-7 showed that power density, working pressure, plasma-facing area and materials, and pumping speed are the main factors influencing the co-deposit removal rates during O-ICR wall conditioning.