跳到主要导航 跳到搜索 跳到主要内容

Comparison of four control methods to active power filters applied in accelerator power supplies

  • Xi'an Jiaotong University

科研成果: 书/报告/会议事项章节会议稿件同行评审

8 引用 (Scopus)

摘要

This paper proposes a hybrid filter structure consisting of a passive power filter and a DC active power filter (DCAPF) applied in high current, high precision and low ripple accelerator power supplies. The configuration of the power system with the DCAPF is firstly introduced. Then four control schemes to obtain the reference signal for the DCAPF control circuit is presented. For each method, the basic operation principle of eliminating output voltage and current ripples is analyzed in detail. Furthermore, the compensation characteristics of each method is discussed and compared. To verify the proposed circuit configuration and the control methods, the testing results of the practical field operation of the DCAPF with a 120kW accelerator power supply is introduced. By adopting the control method of detecting the load ripple voltage, the output current ripple factor and tracking accuracy of the accelerator power supply achieve 8.87 × 10-6(peak-to-peak) and 1 × 10 -4 respectively, which is very satisfactory for this kind of power supplies. The dynamic response of the accelerator power supply is also greatly improved through the application of the DCAPF.

源语言英语
主期刊名2004 IEEE 35th Annual Power Electronics Specialists Conference, PESC4
794-799
页数6
DOI
出版状态已出版 - 2004
活动2004 IEEE 35th Annual Power Electronics Specialists Conference, PESC04 - Aachen, 德国
期限: 20 6月 200425 6月 2004

出版系列

姓名PESC Record - IEEE Annual Power Electronics Specialists Conference
1
ISSN(印刷版)0275-9306

会议

会议2004 IEEE 35th Annual Power Electronics Specialists Conference, PESC04
国家/地区德国
Aachen
时期20/06/0425/06/04

学术指纹

探究 'Comparison of four control methods to active power filters applied in accelerator power supplies' 的科研主题。它们共同构成独一无二的学术指纹。

引用此