TY - JOUR
T1 - Comparison of Direct Pore-Scale and Volume-Averaging Methods for the Performance Evaluation of Porous Volumetric Solar Receiver
AU - Du, Shen
AU - He, Yaling
AU - Li, Dong
AU - Liu, Zhanbin
AU - Li, Mengjie
N1 - Publisher Copyright:
© Science Press, Institute of Engineering Thermophysics, CAS and Springer-Verlag GmbH Germany, part of Springer Nature 2024.
PY - 2024/9
Y1 - 2024/9
N2 - Direct pore-scale and volume-averaging numerical simulations are two methods for investigating the performance of porous volumetric solar receivers. To clarify the difference in the prediction of heat transfer processes, a direct comparison between these two methods was conducted at both steady state and transient state. The numerical models were established based on X-ray computed tomography scans and a local thermal non-equilibrium model, respectively. The empirical parameters, which are indispensable to the volume-averaging simulation, were determined by Monte Carlo ray tracing and direct pore-scale numerical simulations. The predicted outlet air temperature of the receiver by the volume-averaging simulation method corresponded satisfactorily to that in the direct pore-scale simulation. The largest discrepancies were observed when the receiver’s working temperature was elevated, with differences of 5.5% and 3.68% for the steady state and transient state simulations, respectively. However, the volume-averaging method is incapable of capturing the local temperature information of the air and porous skeleton. It underestimates the inlet temperature of the receiver, leading to an overestimation of the receiver’s thermal efficiency, with the largest difference being 6.51%. The comparison results show that the volume-averaging model is a good approximation to the pore-scale model when the empirical parameters are carefully selected.
AB - Direct pore-scale and volume-averaging numerical simulations are two methods for investigating the performance of porous volumetric solar receivers. To clarify the difference in the prediction of heat transfer processes, a direct comparison between these two methods was conducted at both steady state and transient state. The numerical models were established based on X-ray computed tomography scans and a local thermal non-equilibrium model, respectively. The empirical parameters, which are indispensable to the volume-averaging simulation, were determined by Monte Carlo ray tracing and direct pore-scale numerical simulations. The predicted outlet air temperature of the receiver by the volume-averaging simulation method corresponded satisfactorily to that in the direct pore-scale simulation. The largest discrepancies were observed when the receiver’s working temperature was elevated, with differences of 5.5% and 3.68% for the steady state and transient state simulations, respectively. However, the volume-averaging method is incapable of capturing the local temperature information of the air and porous skeleton. It underestimates the inlet temperature of the receiver, leading to an overestimation of the receiver’s thermal efficiency, with the largest difference being 6.51%. The comparison results show that the volume-averaging model is a good approximation to the pore-scale model when the empirical parameters are carefully selected.
KW - pore-scale method
KW - porous media
KW - thermal performance
KW - volume-averaging method
KW - volumetric solar receiver
UR - https://www.scopus.com/pages/publications/85201274520
U2 - 10.1007/s11630-024-2019-8
DO - 10.1007/s11630-024-2019-8
M3 - 文章
AN - SCOPUS:85201274520
SN - 1003-2169
VL - 33
SP - 1607
EP - 1617
JO - Journal of Thermal Science
JF - Journal of Thermal Science
IS - 5
ER -