TY - JOUR
T1 - Comparison and Correction of Errors Caused by Radial Phase-Shifting Nonuniformity of Test Optics in Multi-Step Phase-Shifting
AU - Gao, Fen
AU - Ni, Jinping
AU - Li, Bing
AU - Tian, Ailing
N1 - Publisher Copyright:
© 2018, Chinese Lasers Press. All right reserved.
PY - 2018/4/10
Y1 - 2018/4/10
N2 - Errors causesd by radial phase-shifting nonuniformity of test optics are different when using different steps of phase-shifting algorithms to process interference fringes. Here, a error analysis model is established based on optical principle of point diffraction interferometery. Take 5, 6, 7 and 13 step phase-shifting algorithms as example, phase-shifting errors which are directly caused by radial phase-shifting nonuniformity are first analyzed, and then be introduced into the interferometry model. The influence of this phase-shifting error to final optical surface testing results are analyzed later and a new polynomial error correction method based on error preestimate is proposed. The analysis results show that the more the phase-shifting steps are, the larger the figure error caused by radial phase-shifting nonuniformity is. Each of these figure error shows a paraboloid like distribution. Also, removing the defocus item from Zernike polynomial of final optical surface testing results is equal to have had a quadratic polynomial correction of this error. If the numerical aperture of test optics are no more than 0.3, the error caused by radial phase-shifting nonuniformity can be ignored after the quadratic polynomial correction.
AB - Errors causesd by radial phase-shifting nonuniformity of test optics are different when using different steps of phase-shifting algorithms to process interference fringes. Here, a error analysis model is established based on optical principle of point diffraction interferometery. Take 5, 6, 7 and 13 step phase-shifting algorithms as example, phase-shifting errors which are directly caused by radial phase-shifting nonuniformity are first analyzed, and then be introduced into the interferometry model. The influence of this phase-shifting error to final optical surface testing results are analyzed later and a new polynomial error correction method based on error preestimate is proposed. The analysis results show that the more the phase-shifting steps are, the larger the figure error caused by radial phase-shifting nonuniformity is. Each of these figure error shows a paraboloid like distribution. Also, removing the defocus item from Zernike polynomial of final optical surface testing results is equal to have had a quadratic polynomial correction of this error. If the numerical aperture of test optics are no more than 0.3, the error caused by radial phase-shifting nonuniformity can be ignored after the quadratic polynomial correction.
KW - Error analysis
KW - Interferometry
KW - Measurement
KW - Multi-step phase-shifting
KW - Point diffraction interferometer
KW - Radial phase-shifting nonuniformity
UR - https://www.scopus.com/pages/publications/85050855903
U2 - 10.3788/AOS201838.0412002
DO - 10.3788/AOS201838.0412002
M3 - 文章
AN - SCOPUS:85050855903
SN - 0253-2239
VL - 38
JO - Guangxue Xuebao/Acta Optica Sinica
JF - Guangxue Xuebao/Acta Optica Sinica
IS - 4
M1 - 0412002
ER -