TY - GEN
T1 - Compact Design for 550 kV GIS Insulation System
AU - Wang, Chao
AU - Li, Wen Dong
AU - Jiang, Zhi Hui
AU - Yin, Hao Yang
AU - Yang, Xiong
AU - Zhang, Guan Jun
AU - Zhang, Yi Fan
AU - Fu, Ming Li
AU - Luo, Bing
N1 - Publisher Copyright:
© 2021 IEEE.
PY - 2021/4/11
Y1 - 2021/4/11
N2 - To reduce the usage of SF6gas, downsize equipment's volume, and enhance basin-type spacers' electrical and mechanical performance in gas insulated metal enclosed switchgear (GIS), compact design of spacer based on finite element method is conducted. In the context of reducing 15% insulation distance, electrical and mechanical properties can be improved by optimizing spacer's structure and dielectric properties distribution concurrently. Local concentrated mechanical stress and deformation amount under the pressure of 2.4 MPa are relieved. Besides, surface electric field is well-distributed by adjusting spacer's profiles, thickness at two terminals, and permittivity distribution at the region nearby the flange, resulting in ideal reverse 'U' shape distribution. Comparing with original insulation system, structure after compact design shows approximately 20% decrease of SF6 usage amount and 11.9% reduction of epoxy composite weight. Moreover, the maximum electric field intensity along the convex or concave, and the maximum deformation of spacer could decrease by 17.0%, 21.2%, and 29.9%, respectively. This design strategy for GIS insulation system takes both electrical and mechanical properties into account, and exhibits significant improvement of comprehensive performance of spacer.
AB - To reduce the usage of SF6gas, downsize equipment's volume, and enhance basin-type spacers' electrical and mechanical performance in gas insulated metal enclosed switchgear (GIS), compact design of spacer based on finite element method is conducted. In the context of reducing 15% insulation distance, electrical and mechanical properties can be improved by optimizing spacer's structure and dielectric properties distribution concurrently. Local concentrated mechanical stress and deformation amount under the pressure of 2.4 MPa are relieved. Besides, surface electric field is well-distributed by adjusting spacer's profiles, thickness at two terminals, and permittivity distribution at the region nearby the flange, resulting in ideal reverse 'U' shape distribution. Comparing with original insulation system, structure after compact design shows approximately 20% decrease of SF6 usage amount and 11.9% reduction of epoxy composite weight. Moreover, the maximum electric field intensity along the convex or concave, and the maximum deformation of spacer could decrease by 17.0%, 21.2%, and 29.9%, respectively. This design strategy for GIS insulation system takes both electrical and mechanical properties into account, and exhibits significant improvement of comprehensive performance of spacer.
KW - compact design
KW - gas insulated switchgear
KW - geometrical optimization
KW - permittivity distribution optimization
UR - https://www.scopus.com/pages/publications/85114052718
U2 - 10.1109/ICEMPE51623.2021.9509127
DO - 10.1109/ICEMPE51623.2021.9509127
M3 - 会议稿件
AN - SCOPUS:85114052718
T3 - ICEMPE 2021 - 3rd International Conference on Electrical Materials and Power Equipment
BT - ICEMPE 2021 - 3rd International Conference on Electrical Materials and Power Equipment
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 3rd International Conference on Electrical Materials and Power Equipment, ICEMPE 2021
Y2 - 11 April 2021 through 15 April 2021
ER -