A novel swirl burner with adjustable inner secondary air flaring angle β is proposed and tested in an opposed fired pilot-scale furnace. The influences of five different flaring angles (β = 11.4/17.1/26/31.7/35.5) are studied on combustion and emissions under different air distributions. Two different rank coals are used. Changing β with air distribution helps coal ignition and promotes burning temperature level. Low-rank coal requires larger β for ignition and burning fiercely than high-rank coal. Enlarging β to 31.7° helps to decrease CO emission effectively. The specific β corresponding to a certain air distribution can limit NOx emission further. The high burnout of two coals corresponds to different β of burner. Inner secondary air flaring angle variation, combining with air distribution adjustment, can improve coal adaption, and help burning more effectively and cleaning.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 44-53 |
| 页数 | 10 |
| 期刊 | Applied Thermal Engineering |
| 卷 | 79 |
| DOI | |
| 出版状态 | 已出版 - 25 3月 2015 |