TY - JOUR
T1 - Clinical application of 3D-printed PEEK implants for repairing mandibular defects
AU - Li, Yunpeng
AU - Li, Zhiye
AU - Tian, Lei
AU - Li, Dichen
AU - Lu, Bin
AU - Shi, Changquan
AU - Niu, Qiang
AU - Liu, Fuwei
AU - Kong, Liang
AU - Zhang, Junrui
N1 - Publisher Copyright:
© 2022 European Association for Cranio-Maxillo-Facial Surgery
PY - 2022/8
Y1 - 2022/8
N2 - The aim of this study was to investigate and discuss the efficacy of 3D-printed PEEK implants in personalized reconstruction of mandibular segmental defects. This study was a single-center case series. Six patients who underwent mandibular reconstruction with a custom-made 3D-printed PEEK implant were enrolled. Patient demographics, photographs, computed tomography (CT), and other clinical data were collected and analyzed pre- and postoperatively. The average patient age was 60.0 ± 15.09 years. The mean operative time was 213.33 ± 30.77 min, and the postoperative follow-up time ranged from 10 to 24 months. Mandibular segmental defects ranged from the symphysis to the condyle. Five patients did not have any postoperative complications and were satisfied with the cosmetic and functional results. One patient had to undergo removal of the PEEK implant because of implant exposure at 10 months after surgery. PEEK implants can repair different forms of defect in the mandible, maintaining the original shape of the mandible, whilst not affecting mandible functions, such as mastication and temporomandibular joint movement. However, PEEK implantation requires the strict selection of appropriate indications, especially with regard to the evaluation of soft-tissue conditions in the implanted area.
AB - The aim of this study was to investigate and discuss the efficacy of 3D-printed PEEK implants in personalized reconstruction of mandibular segmental defects. This study was a single-center case series. Six patients who underwent mandibular reconstruction with a custom-made 3D-printed PEEK implant were enrolled. Patient demographics, photographs, computed tomography (CT), and other clinical data were collected and analyzed pre- and postoperatively. The average patient age was 60.0 ± 15.09 years. The mean operative time was 213.33 ± 30.77 min, and the postoperative follow-up time ranged from 10 to 24 months. Mandibular segmental defects ranged from the symphysis to the condyle. Five patients did not have any postoperative complications and were satisfied with the cosmetic and functional results. One patient had to undergo removal of the PEEK implant because of implant exposure at 10 months after surgery. PEEK implants can repair different forms of defect in the mandible, maintaining the original shape of the mandible, whilst not affecting mandible functions, such as mastication and temporomandibular joint movement. However, PEEK implantation requires the strict selection of appropriate indications, especially with regard to the evaluation of soft-tissue conditions in the implanted area.
KW - 3D printing
KW - Mandibular defect
KW - Maxillofacial surgery
KW - polyether Ether ketone
UR - https://www.scopus.com/pages/publications/85133300025
U2 - 10.1016/j.jcms.2022.06.002
DO - 10.1016/j.jcms.2022.06.002
M3 - 文章
C2 - 35760658
AN - SCOPUS:85133300025
SN - 1010-5182
VL - 50
SP - 621
EP - 626
JO - Journal of Cranio-Maxillofacial Surgery
JF - Journal of Cranio-Maxillofacial Surgery
IS - 8