TY - JOUR
T1 - Blind CT Image Quality Assessment Using DDPM-Derived Content and Transformer-Based Evaluator
AU - Shi, Yongyi
AU - Xia, Wenjun
AU - Wang, Ge
AU - Mou, Xuanqin
N1 - Publisher Copyright:
©1982-2012 IEEE.
PY - 2024
Y1 - 2024
N2 - Lowering radiation dose per view and utilizing sparse views per scan are two common CT scan modes, albeit often leading to distorted images characterized by noise and streak artifacts. Blind image quality assessment (BIQA) strives to evaluate perceptual quality in alignment with what radiologists perceive, which plays an important role in advancing low-dose CT reconstruction techniques. An intriguing direction involves developing BIQA methods that mimic the operational characteristic of the human visual system (HVS). The internal generative mechanism (IGM) theory reveals that the HVS actively deduces primary content to enhance comprehension. In this study, we introduce an innovative BIQA metric that emulates the active inference process of IGM. Initially, an active inference module, implemented as a denoising diffusion probabilistic model (DDPM), is constructed to anticipate the primary content. Then, the dissimilarity map is derived by assessing the interrelation between the distorted image and its primary content. Subsequently, the distorted image and dissimilarity map are combined into a multi-channel image, which is inputted into a transformer-based image quality evaluator. By leveraging the DDPM-derived primary content, our approach achieves competitive performance on a low-dose CT dataset.
AB - Lowering radiation dose per view and utilizing sparse views per scan are two common CT scan modes, albeit often leading to distorted images characterized by noise and streak artifacts. Blind image quality assessment (BIQA) strives to evaluate perceptual quality in alignment with what radiologists perceive, which plays an important role in advancing low-dose CT reconstruction techniques. An intriguing direction involves developing BIQA methods that mimic the operational characteristic of the human visual system (HVS). The internal generative mechanism (IGM) theory reveals that the HVS actively deduces primary content to enhance comprehension. In this study, we introduce an innovative BIQA metric that emulates the active inference process of IGM. Initially, an active inference module, implemented as a denoising diffusion probabilistic model (DDPM), is constructed to anticipate the primary content. Then, the dissimilarity map is derived by assessing the interrelation between the distorted image and its primary content. Subsequently, the distorted image and dissimilarity map are combined into a multi-channel image, which is inputted into a transformer-based image quality evaluator. By leveraging the DDPM-derived primary content, our approach achieves competitive performance on a low-dose CT dataset.
KW - Blind image quality assessment
KW - denoising diffusion probabilistic model (DDPM)
KW - primary content
KW - transformer-based image quality evaluator
UR - https://www.scopus.com/pages/publications/85197071964
U2 - 10.1109/TMI.2024.3418652
DO - 10.1109/TMI.2024.3418652
M3 - 文章
C2 - 38913529
AN - SCOPUS:85197071964
SN - 0278-0062
VL - 43
SP - 3559
EP - 3569
JO - IEEE Transactions on Medical Imaging
JF - IEEE Transactions on Medical Imaging
IS - 10
ER -