TY - JOUR
T1 - Asymmetric phenomenon of flow and mass transfer in symmetric cylindrical and semi-cylindrical shallow chambers
AU - Li, Yubing
AU - Yang, Mo
AU - Zhang, Yuwen
N1 - Publisher Copyright:
© 2021 Elsevier Ltd
PY - 2021/4
Y1 - 2021/4
N2 - Numerical simulations are presented for three-dimensional flow and mass transfer of semi-volatile organic compounds (SVOCs) in cylindrical and semi-cylindrical shallow chambers (Chambers A and B thereafter). The effects of the Reynolds numbers, ranging from 2 to 1100, on velocity and concentration field are considered in the one-quarter domain, the half domain, and the entire domain of chambers. The results show that at low Reynolds number, the streamline and concentration distribution are unique and symmetric. When Re exceeds the critical Reynolds numbers, Rec, asymmetric flow and mass transfer occur in Chamber A in the Y-planes and Chamber B in both the Y- and Z-planes. The critical Reynolds numbers in Chamber A and B are 952 and 1054, respectively. At Re = 1013, steady symmetric and asymmetric solutions are both obtained in Chamber A, and the asymmetric convective mass transfer coefficient increases by 1.52% compared with the symmetric result. The asymmetric convection in Chamber B decreases 3.45% of the Sherwood number than the symmetric flow. As the Reynolds number increases, the mass transfer efficiency increases in both chambers. The velocity field from the special structure of Chamber B leads to a stronger convective mass transfer.
AB - Numerical simulations are presented for three-dimensional flow and mass transfer of semi-volatile organic compounds (SVOCs) in cylindrical and semi-cylindrical shallow chambers (Chambers A and B thereafter). The effects of the Reynolds numbers, ranging from 2 to 1100, on velocity and concentration field are considered in the one-quarter domain, the half domain, and the entire domain of chambers. The results show that at low Reynolds number, the streamline and concentration distribution are unique and symmetric. When Re exceeds the critical Reynolds numbers, Rec, asymmetric flow and mass transfer occur in Chamber A in the Y-planes and Chamber B in both the Y- and Z-planes. The critical Reynolds numbers in Chamber A and B are 952 and 1054, respectively. At Re = 1013, steady symmetric and asymmetric solutions are both obtained in Chamber A, and the asymmetric convective mass transfer coefficient increases by 1.52% compared with the symmetric result. The asymmetric convection in Chamber B decreases 3.45% of the Sherwood number than the symmetric flow. As the Reynolds number increases, the mass transfer efficiency increases in both chambers. The velocity field from the special structure of Chamber B leads to a stronger convective mass transfer.
KW - Mass transfer
KW - Pitchfork bifurcation
KW - SVOCs
KW - Shallow cylindrical chambers
UR - https://www.scopus.com/pages/publications/85101342207
U2 - 10.1016/j.icheatmasstransfer.2021.105174
DO - 10.1016/j.icheatmasstransfer.2021.105174
M3 - 文章
AN - SCOPUS:85101342207
SN - 0735-1933
VL - 123
JO - International Communications in Heat and Mass Transfer
JF - International Communications in Heat and Mass Transfer
M1 - 105174
ER -