Application of Transesophageal Echocardiography in Amplatzer Atrial Septal Defect Occluder for Percutaneous Closure of Large Patent Foramen Ovale

  • Yajuan Du
  • , Hang Xie
  • , Hui Shao
  • , Gesheng Cheng
  • , Lu He
  • , Xingye Wang
  • , Xumei He
  • , Beidi Lan
  • , Yushun Zhang
  • , Gang Tian
  • The First Affiliated Hospital of Xi’an Jiaotong University

科研成果: 期刊稿件 › 文章 › 同行评审

4 引用 (Scopus)

摘要

Objective. The Amplatzer patent foramen ovale (PFO) occluder is the most commonly used device for percutaneous closure of a large PFO. However, its use may predispose the patient to postoperative residual shunting. To reduce the incidence of residual shunting, we investigated the safety and effectiveness of the Amplatzer atrial septal defect (ASD) occluder for percutaneous closure of a large PFO measured by transesophageal echocardiography (TEE) and evaluated the value of TEE in this procedure. Methods. Overall, 118 patients who were diagnosed with a large PFO (all with a≥2 mm left atrial side height after the Valsalva maneuver (VM) excluding those with a small ASD) using contrast transthoracic echocardiography (c-TTE) and TEE underwent closure under TEE guidance at The First Affiliated Hospital of Xi'an Jiaotong University. An ASD device was used in 48 patients (group I) and a PFO device in 70 (group II). After the procedure, we verified the safety and efficacy of different devices using c-TTE, TTE, and TEE. Results. In both groups, the preoperative TEE results showed a significantly increased left height of the PFO after VM compared with that at rest (all P<0.01). Compared with the left height of the PFO measured using TEE after VM, the PFO-stretch diameter (SD) measured by TEE after the delivery sheath passed the PFO was higher (all P<0.01). We selected the ASD occluder size according to this PFO-SD. In group II, most patients underwent the implantation of the larger PFO devices. Interventional treatment was successfully performed on all patients. The effective occlusion rate in group I at 12 months after the procedure was significantly higher than that in group II (93.7% vs. 78.6%, P<0.05). The TEE results showed that 18 patients with a medium and large residual shunt at 12 months after the procedure exhibited an intradisc tunnel-like shunt. Conclusion. The Amplatzer ASD device and Amplatzer PFO device are safe for large PFO closure, but the Amplatzer ASD device has a higher effective occlusion rate. TEE plays a crucial role in the use of the Amplatzer ASD occluder for percutaneous closure of a large PFO.

源语言英语
期刊论文编号3226080
期刊Cardiovascular Therapeutics
卷2022
DOI
出版状态已出版 - 2022
已对外发布是

学术指纹

探究 'Application of Transesophageal Echocardiography in Amplatzer Atrial Septal Defect Occluder for Percutaneous Closure of Large Patent Foramen Ovale' 的科研主题。它们共同构成独一无二的学术指纹。

引用此