TY - JOUR
T1 - Analysis of the natural circulation test of PHENIX reactor by the THACS code
AU - Liu, Yapeng
AU - Zhang, Dalin
AU - Song, Ping
AU - Wang, Shibao
AU - Liang, Yu
AU - Zhou, Lei
AU - Wang, Chenglong
AU - Wang, Mingjun
AU - Tian, Wenxi
AU - Qiu, Suizheng
AU - Su, G. H.
N1 - Publisher Copyright:
© 2020 Elsevier Ltd
PY - 2021/3
Y1 - 2021/3
N2 - For the pool type sodium-cooled fast reactor (SFR), whether the primary circuit can establish a stable natural cycle after the reactor accident, and whether the primary natural cycle can take away the decay heat of the reactor core in the long-term, are the key issues in the design and safety analysis of SFR. In order to verify the natural circulation capacity of the primary circuit, a natural circulation test was carried out on pool type SFR Phenix by CEA before the reactor is decommissioned. One objective of this test is to verify the system codes used to simulate sodium natural convection phenomena. In this paper, the system code THACS is used to analyze Phenix natural circulation test, and the capacity of THACS to analyze the natural circulation of SFR is evaluated. Firstly, this paper introduces the components of Phenix reactor and the process of natural circulation test. Then, the models of program and the computational modeling of Phenix reactor are described. The calculation involves the whole process of the test: dry out of steam generators, scram, stop of pumps, two phases of natural circulation. Then, the results are compared with the test data, and the influence of inter-wrapper flow (IWF) on core outlet temperature is emphasized. The results show good applicability of THACS to analyze natural circulation in SFR, and the IWF can reduce the peak value of core outlet temperature at the beginning of natural cycle. Finally, the deviation between calculation and test results are analyzed, and the limitation of the models are evaluated.
AB - For the pool type sodium-cooled fast reactor (SFR), whether the primary circuit can establish a stable natural cycle after the reactor accident, and whether the primary natural cycle can take away the decay heat of the reactor core in the long-term, are the key issues in the design and safety analysis of SFR. In order to verify the natural circulation capacity of the primary circuit, a natural circulation test was carried out on pool type SFR Phenix by CEA before the reactor is decommissioned. One objective of this test is to verify the system codes used to simulate sodium natural convection phenomena. In this paper, the system code THACS is used to analyze Phenix natural circulation test, and the capacity of THACS to analyze the natural circulation of SFR is evaluated. Firstly, this paper introduces the components of Phenix reactor and the process of natural circulation test. Then, the models of program and the computational modeling of Phenix reactor are described. The calculation involves the whole process of the test: dry out of steam generators, scram, stop of pumps, two phases of natural circulation. Then, the results are compared with the test data, and the influence of inter-wrapper flow (IWF) on core outlet temperature is emphasized. The results show good applicability of THACS to analyze natural circulation in SFR, and the IWF can reduce the peak value of core outlet temperature at the beginning of natural cycle. Finally, the deviation between calculation and test results are analyzed, and the limitation of the models are evaluated.
KW - Inter-wrapper flow
KW - Natural circulation
KW - Phenix end-of-life test
KW - Program verification
KW - Sodium-cooled fast reactor
KW - THACS
UR - https://www.scopus.com/pages/publications/85097075080
U2 - 10.1016/j.anucene.2020.108022
DO - 10.1016/j.anucene.2020.108022
M3 - 文章
AN - SCOPUS:85097075080
SN - 0306-4549
VL - 152
JO - Annals of Nuclear Energy
JF - Annals of Nuclear Energy
M1 - 108022
ER -