跳到主要导航 跳到搜索 跳到主要内容

Analysis of signal distortion caused by opening ratio variation of main scale and index scale in linear encoder

  • Xuan Li
  • , Lei Yin
  • , Yong Sheng Shi
  • , Guo Yong Ye
  • , Hao Yu Yu
  • , Hong Zhong Liu
  • Xi'an Jiaotong University

科研成果: 书/报告/会议事项章节会议稿件同行评审

7 引用 (Scopus)

摘要

Linear encoder as an important displacement measurement device has been widely used in manufacturing industry. The accuracy of linear encoder is based on the precision of its scales. In this article, the manufacturing process of the scales based on photolithography process and etching process was discussed in order to explain the opening ratio variation. A mathematical model was derived to analyze the effects of opening ratio variation on the waveform of output signal. The result shows that the waveform of the signal is cut off in comparison with the ideal waveform, and the magnitude of the output signal is changed.

源语言英语
主期刊名Advances in Manufacturing Science and Engineering
1833-1837
页数5
DOI
出版状态已出版 - 2013
活动4th International Conference on Manufacturing Science and Engineering, ICMSE 2013 - Dalian, 中国
期限: 30 3月 201331 3月 2013

出版系列

姓名Advanced Materials Research
712-715
ISSN(印刷版)1022-6680

会议

会议4th International Conference on Manufacturing Science and Engineering, ICMSE 2013
国家/地区中国
Dalian
时期30/03/1331/03/13

学术指纹

探究 'Analysis of signal distortion caused by opening ratio variation of main scale and index scale in linear encoder' 的科研主题。它们共同构成独一无二的学术指纹。

引用此