跳到主要导航 跳到搜索 跳到主要内容

Analysis of boost PFC converters operating in the discontinuous conduction mode

  • University of Liverpool

科研成果: 期刊稿件 › 文章 › 同行评审

51 引用 (Scopus)

摘要

As power factor correction (PFC) converters for low-power applications usually operate in the discontinuous conduction mode (DCM), operating in continuous conduction mode (CCM) will produce input current distortion. This distortion can be observed in a few switching cycles of one line cycle. Asynchronous switching maps are derived to obtain the time-domain waveforms of input current and output voltage. It can be seen that the cause of the distortion is the change in the current conduction mode. A model for PFC converters operating in DCM with fixed switching frequency and duty-ratio is developed, which can predict the converter operation mode under practical circumstances. Analysis of the output voltage and power limitations is provided based on the proposed model. Simulation and experimental results are presented to verify the proposed method.

源语言英语
期刊论文编号5898425
页(从-至)3621-3628
页数8
期刊IEEE Transactions on Power Electronics
卷26
期12
DOI
出版状态已出版 - 2011
已对外发布是

学术指纹

探究 'Analysis of boost PFC converters operating in the discontinuous conduction mode' 的科研主题。它们共同构成独一无二的学术指纹。

引用此