摘要
A six-stage gas switch developed for linear transformer drivers is presented in this paper. The switch features an easy-handling structure consisting of stackable cylindrical insulators and brimmed toroidal electrodes. Following an electrode conditioning procedure, the switch and one of its gaps undergo self-breakdown tests by which normal distribution parameters of the self-breakdown voltage at each experimental air pressure are determined. Assuming that all gaps are the same, the switch's voltage with a 50% self-breakdown probability is predicted as the summed voltage of six gaps which individually have a 10.9% self-breakdown probability of voltage being calculated by using the experimentally determined normal function. The calculated result is 7-14 kV higher than the measured voltage because of a nonuniform voltage distribution which is later confirmed by using unequal gaps. For a more uniform voltage distribution, electrodes are revised to suppress corona discharge, and this revision has finally increased the switch hold-off voltage by 4-6 kV, which is the same as a resistive divider.
| 源语言 | 英语 |
|---|---|
| 文章编号 | 6353973 |
| 页(从-至) | 187-191 |
| 页数 | 5 |
| 期刊 | IEEE Transactions on Plasma Science |
| 卷 | 41 |
| 期 | 1 |
| DOI | |
| 出版状态 | 已出版 - 2013 |
| 已对外发布 | 是 |
学术指纹
探究 'Analysis and enhancing of self-breakdown voltages of a multistage gas switch' 的科研主题。它们共同构成独一无二的指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver