TY - GEN
T1 - An Two-Stage Harmonic Optimization Method For Optimal Sitting and Sizing of APFs in Distribution Networks to Minimize THDs and Harmonic Losses
AU - Yin, Xiaoqing
AU - Yi, Hao
AU - Yang, Zebin
AU - Liu, Yang
AU - Liu, Wenbin
AU - Zhang, Yao
N1 - Publisher Copyright:
© 2024 IEEE.
PY - 2024
Y1 - 2024
N2 - With the massive application of distributed generation and new flexible loads, the characteristics of nonlinear loads distributed access pose significant challenges to the traditional "point-to-point"harmonic mitigation approach in the distribution network. The technology of multi-machine coordinated harmonic mitigation of active power filters (APFs) at the network side of the distribution network has emerged. However, current coordinated control schemes of APFs mainly focus on harmonic distortion indices while neglecting the optimization of harmonic loss, which is also an important indicator affecting the safe and stable operation of the distribution network. Hence, this paper proposes a two-stage network-level harmonic suppression method for sitting and sizing a few APFs, aiming at both harmonic suppression and reduction of harmonic loss in the distribution networks. This method not only considers harmonic distortion and harmonic loss mitigation but also reduces control costs and improves the operational stability of distribution networks.
AB - With the massive application of distributed generation and new flexible loads, the characteristics of nonlinear loads distributed access pose significant challenges to the traditional "point-to-point"harmonic mitigation approach in the distribution network. The technology of multi-machine coordinated harmonic mitigation of active power filters (APFs) at the network side of the distribution network has emerged. However, current coordinated control schemes of APFs mainly focus on harmonic distortion indices while neglecting the optimization of harmonic loss, which is also an important indicator affecting the safe and stable operation of the distribution network. Hence, this paper proposes a two-stage network-level harmonic suppression method for sitting and sizing a few APFs, aiming at both harmonic suppression and reduction of harmonic loss in the distribution networks. This method not only considers harmonic distortion and harmonic loss mitigation but also reduces control costs and improves the operational stability of distribution networks.
KW - Lagrange multiplier method
KW - active power filter
KW - distribution network
KW - harmonic loss
KW - optimal allocation
KW - total harmonic distortion
UR - https://www.scopus.com/pages/publications/85211760411
U2 - 10.1109/ECCEEurope62508.2024.10751801
DO - 10.1109/ECCEEurope62508.2024.10751801
M3 - 会议稿件
AN - SCOPUS:85211760411
T3 - ECCE Europe 2024 - Energy Conversion Congress and Expo Europe, Proceedings
BT - ECCE Europe 2024 - Energy Conversion Congress and Expo Europe, Proceedings
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2024 Energy Conversion Congress and Expo Europe, ECCE Europe 2024
Y2 - 2 September 2024 through 6 September 2024
ER -