跳到主要导航 跳到搜索 跳到主要内容

An Isolated Capacitor-Compensated Current Sensing Method for High-Frequency Resonant Converters

  • Nanyang Technological University
  • Xi'an Jiaotong University

科研成果: 期刊稿件 › 文章 › 同行评审

10 引用 (Scopus)

摘要

In high-frequency resonant converters, current transformers (CTs) are commonly used to measure the currents of the resonant tank for protection, feedback control, synchronous drive, etc. However, CTs may generate large power losses when measuring high-frequency large currents, which makes it difficult to miniaturize. This letter proposed an alternative isolated current sensing method. The method uses a transformer and a resistor to compensate the resonant capacitor to obtain the current flowing through the capacitor. Compared with the CTs, the proposed method can be much smaller and more efficient, because the current flowing through the transformer is significantly reduced. In the experiments, the transformer size of the proposed method is only 1/7 of that of the CT. The transformer temperature in the proposed method is only 54.7 °C, while that in the CT is as high as 116 °C when simultaneously measuring a 1 MHz, 12.5 A current. Besides, the experimental results show that the proposed method has good linearity and wide bandwidth.

源语言英语
期刊论文编号8572774
页(从-至)6009-6013
页数5
期刊IEEE Transactions on Power Electronics
卷34
期7
DOI
出版状态已出版 - 7月 2019

学术指纹

探究 'An Isolated Capacitor-Compensated Current Sensing Method for High-Frequency Resonant Converters' 的科研主题。它们共同构成独一无二的学术指纹。

引用此