跳到主要导航 跳到搜索 跳到主要内容

An investigation on computed tomography image reconstruction with compressed sensing by l1 norm prior image constraints

  • Stony Brook University
  • Southern Medical University

科研成果: 书/报告/会议事项章节 › 会议稿件 › 同行评审

2 引用 (Scopus)

摘要

This paper aims to investigate the problem of low-dose computed tomography (CT) reconstruction with prior image constraints using the compressed sensing (CS) theorem. The CS theorem states that images can be reconstructed from under-sampled data in an adequate or transfer domain without introducing noticeable artifacts by solving a convex optimization problem if the source signals are sparse. To describe the sparsity, a model of piecewise constant source distribution has recently been assumed for image reconstruction by minimizing the total variance (TV) of the image density distribution in the Fourier domain. However, the assumption may not hold for complicated image structures. It has been observed that a prior image from the same subject or anatomy can provide excellent information to the image to be reconstructed. Based on this observation, this study investigates the problem of image reconstruction from under-sampled data by minimizing the difference between the prior image and the concerned image to be estimated with data constraints in the Fourier domain. Compared to the TV criterion, this presented method doesn't require the piecewise constant assumption where the similarity between the two images specifies a new priori model for a new cost function. The presented method was tested by computer simulations using the Shepp-Logan phantom. In noise-free case, only 64 projections around the phantom are needed to produce an accurate reconstruction. The reconstruction remained excellent until the number of projections was reduced to 22 when a high similarity exists between the prior and concerned images while the well-known filtered backprojection reconstruction failed. In cases with noise variance at 1% level, the signal-to-noise of the reconstruction by presented CS-based approach dropped rapidly when the number of projections decreased from 64 to 22. This investigation reveals the high sensitivity of the CS-based approach for low-dose CT image reconstruction. Modification of the cost function to consider data statistics is needed.

源语言英语
主期刊名2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011
出版商Institute of Electrical and Electronics Engineers Inc.
页2682-2687
页数6
ISBN(印刷版)9781467301183
DOI
出版状态已出版 - 2011
已对外发布是
活动2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011 - Valencia, 西班牙
期限: 23 10月 2011 → 29 10月 2011

丛书

姓名IEEE Nuclear Science Symposium Conference Record
ISSN(印刷版)1095-7863

会议

会议2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011
国家/地区西班牙
市Valencia
时期23/10/11 → 29/10/11