摘要
Currently, space-variable, capacitive multi-axis force/torque sensors have limited detection accuracy in the measurement of complex multi-axis loads owing to their inherent nonlinearity and coupling errors in the full range. The nonlinearity and coupling of the conventional capacitance differential equation were experimentally verified for a pre-developed space-variable capacitive six-axis force/torque sensing chip. An inverse capacitance differential decoupling equation was practically applied to the chip to suppress the inherent nonlinearity and coupling errors in the full range (2.5 N and 12.5 N·mm) under multi-axis loads. The results of complex multi-axis coupled loading tests align with the theoretical analysis. When the inverse decoupling equation is adopted, the maximum nonlinearities of 18.59% full scale (FS) and coupling errors of 254.1%FS for the conventional equation can be reduced to 1.05%FS and 10.90%FS, respectively. The efficient decoupling structure combined with the inverse capacitance differential equation can provide critical theoretical guidance for developing high-accuracy capacitive multi-axis force/torque sensors.
| 源语言 | 英语 |
|---|---|
| 期刊论文编号 | 9518213 |
| 期刊 | IEEE Transactions on Instrumentation and Measurement |
| 卷 | 75 |
| DOI | |
| 出版状态 | 已出版 - 2026 |
学术指纹
探究 'An Inverse Capacitance Differential Equation-Based Six-Axis Force/Torque Sensor for the High-Accuracy Decoupling of Complex Multi-Axis Loads' 的科研主题。它们共同构成独一无二的学术指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver