跳到主要导航 跳到搜索 跳到主要内容

Absolute quantification of NAD(P)H: Quinone oxidoreductase 1 in human tumor cell lines and tissues by liquid chromatography-mass spectrometry/mass spectrometry using both isotopic and non-isotopic internal standards

  • Zhiyuan Tang
  • , Mengqiu Wu
  • , Yingchun Li
  • , Xiao Zheng
  • , Huiying Liu
  • , Xuefang Cheng
  • , Lin Xu
  • , Guangji Wang
  • , Haiping Hao
  • China Pharmaceutical University
  • Jiangsu Institute of Cancer Institute & Hospital

科研成果: 期刊稿件 › 文章 › 同行评审

13 引用 (Scopus)

摘要

NAD(P)H:quinone oxidoreductase 1 (NQO1, DT-diaphorase) is a prognostic biomarker and a potential therapeutic target for various tumors. Therefore, it is of significance to develop a robust method for the absolute quantification of NQO1. This study aimed to develop and validate a LC-MS/MS based method and to test the appropriateness of using non-isotopic analog peptide as the internal standard (IS) by comparing with a stable isotope labeled (SIL) peptide. The chromatographic performance and mass spectra between the selected signature peptide of NQO1 and the non-isotopic peptide were observed to be very similar. The use of the two internal standards was validated appropriate for the absolute quantification of NQO1, as evidenced by satisfactory validation results over a concentration range of 1.62-162fmolμL-1. This method has been successfully applied to the absolute quantification of NQO1 expression in various tumor cell lines and tissues. NQO1 expression in human tumor tissues is much higher than that in the neighboring normal tissues in both the cases of lung and colon cancer. The quantitative results obtained from the isotopic and non-isotopic methods are quite similar, further supporting that the use of non-isotopic analog peptide as internal standard is appropriate and feasible for the quantification of NQO1. By comparing with a classical isotopic IS, the present study indicates that the use of a non-isotopic peptide analog to the proteotypic peptide as the internal standard can get equal accuracy and preciseness in measuring NQO1. The universal applicability of the non-isotopic IS approach for the quantification of proteins warrants further research.

源语言英语
页(从-至)59-67
页数9
期刊Analytica Chimica Acta
卷772
DOI
出版状态已出版 - 15 4月 2013
已对外发布是

联合国可持续发展目标

此成果有助于实现下列可持续发展目标:

  1. 可持续发展目标 3 - 良好健康与福祉
    可持续发展目标 3 良好健康与福祉

学术指纹

探究 'Absolute quantification of NAD(P)H: Quinone oxidoreductase 1 in human tumor cell lines and tissues by liquid chromatography-mass spectrometry/mass spectrometry using both isotopic and non-isotopic internal standards' 的科研主题。它们共同构成独一无二的学术指纹。

引用此