跳到主要导航 跳到搜索 跳到主要内容

Abrasive wear studies of nitrogen-implanted aluminium and titanium

  • E. Ma
  • , J. J. Li
  • , H. D. Li
  • Tsinghua University

科研成果: 期刊稿件 › 文章 › 同行评审

8 引用 (Scopus)

摘要

Disks of commercial grade aluminium and titanium were implanted at room temperature with nitrogen ions to doses ranging from 1 × 1016 to 5 × 1017 ions cm-2. The abrasive wear resistance of the implanted layer was tested using a modified polishing machine. The relative wear resistance (RWR) was measured along the wear depth. For both aluminium and titanium an appreciable decrease in wear rate was observed for sample surfaces implanted to doses higher than 1 × 1017 cm-2. The RWR reaches a maximum value of about 4 in the implanted layer close to the sample surface and gradually drops to unity when the implanted layer is removed. X-ray diffraction using Seemann-Bohlin geometry reveals the formation of AIN and TiN in aluminium and titanium respectively after high dose implantation. We attribute the ennoblement of the surface after implantation to the classic hardening mechanisms of solid solution and fine dispersion strengthening. Abrasive wear testing appears to be an appropriate method of evaluating the hardness of the thin surface layer and the effectiveness of implantation.

源语言英语
页(从-至)31-36
页数6
期刊Surface and Coatings Technology
卷37
期1
DOI
出版状态已出版 - 2月 1989
已对外发布是

学术指纹

探究 'Abrasive wear studies of nitrogen-implanted aluminium and titanium' 的科研主题。它们共同构成独一无二的学术指纹。

引用此