跳到主要导航 跳到搜索 跳到主要内容

A synergistic effect of MXene/MWCNT enables self-healable and low percolation elastomer sensor: A combined experiment and all-atom molecular dynamics simulation

  • Zuwei Fu
  • , Qionghai Chen
  • , Junwei He
  • , Sai Li
  • , Rui Ming
  • , Yuan Wei
  • , Yihui Xu
  • , Jun Liu
  • , Liqun Zhang
  • Beijing University of Chemical Technology
  • SINOPEC

科研成果: 期刊稿件文章同行评审

21 引用 (Scopus)

摘要

Flexible conductive composites have garnered significant interest as wearable strain sensors due to their potential in diverse application fields, such as next-generation robotics automation, electronic skin, and human body detection. Nevertheless, the practical usage scenarios often entail tear and fracture, posing a persistent challenge to their performance stability. Consequently, there exists a pressing demand to engineer conductive composites that not only exhibit flexibility, stretchability, and sensing capabilities but also demonstrate effective self-healing properties. This pursuit presents a formidable task, considering the complex requirements imposed on the materials. This study presents a novel methodology for fabricating a conductive silicone elastomer composite. The approach involves the initial utilization of an excess of amino-capped Polydimethylsiloxane (PDMS) to undergo a reaction with Toluene diisocyanate (TDI) and Isoflurane diisocyanate (IPDI), leading to the formation of amino-capped polyurea (TPU). Subsequently, the self-healing elastomer IPDI/TDI/TA (ITT) is synthesized through chain expansion with Terephthalaldehyde (TA) in tetrahydrofuran (THF). To complement the experimental investigations, all-atom molecular dynamics (AAMD) simulations are employed to develop a comprehensive model elucidating the mechanical characteristics and self-healing capabilities of the elastomers. To introduce hybrid fillers into the elastomer composite, MXenes are electrostatically modified with L-glutamine (negatively charged), while multi-walled carbon nanotubes (MWCNTs) are modified with cetyltrimethylammonium bromide (positively charged). These modified fillers self-assemble in water and are subsequently combined with the aforementioned rubber THF solution after drying. Through ultrasonication and drying, the ITT elastomers/MXene/MWCNT composite is successfully prepared. The formation of hydrogen bonds and dynamic imine bonds is verified using FT-IR and AAMD simulations. By maintaining a fixed ratio of TA to PDMS, we observe a positive correlation between TDI concentration and the fracture strength of the ITT elastomer, while the elongation at break decreases with increasing TDI. Furthermore, the successful modification of MXene and MWCNT is confirmed through FT-IR, XRD, and zeta potential measurements, and the resulting composites exhibit significant electrical conductivity and self-healing properties. Tensile and electrochemical measurements demonstrate that the composite possesses promising characteristics suitable for sensor applications, and its mechanical and electrical properties can recover after self-healing. Notably, the resulting composites exhibit a very low conductivity threshold (3.5 wt%). The composite system exhibits desirable tensile properties and efficient self-healing ability due to the reversibility of multiple hydrogen and imine bonds. Overall, this study aims to introduce a novel elastomer-based composite that possesses excellent properties in terms of self-healing, stretchability, sensing capability and flexibility.

源语言英语
文章编号110155
期刊Composites Science and Technology
242
DOI
出版状态已出版 - 29 9月 2023
已对外发布

学术指纹

探究 'A synergistic effect of MXene/MWCNT enables self-healable and low percolation elastomer sensor: A combined experiment and all-atom molecular dynamics simulation' 的科研主题。它们共同构成独一无二的指纹。

引用此