TY - JOUR
T1 - A symbiotic skin hydrogel interface enabled by flexible hydrogel network with embedded enhancement structure
AU - Ma, Jun
AU - Wang, Mingxu
AU - Wang, Yongfeng
AU - Wu, Qian
AU - Zhou, Cunkai
AU - Zhou, Yuchen
AU - Ge, Changlei
AU - Guo, Jixiao
AU - Zhao, Feijun
AU - Hao, Mingming
AU - Fan, Chonghui
AU - Wen, Feng
AU - Wang, Shuqi
AU - Liu, Mengyuan
AU - Liu, Yujie
AU - Shen, Hao
AU - Li, Lianhui
AU - Zhang, Ting
N1 - Publisher Copyright:
© The Author(s) 2026.
PY - 2026/12
Y1 - 2026/12
N2 - Wearable electrophysiological monitoring based on hydrogel electrodes is pivotal for decoding the body’s “electrical language”, yet fundamentally hampered by the unstable mechano-electrical interface between flexible electrodes and the skin caused by dehydration and poor breathability. Here, we demonstrate a symbiotic interface between an embedded-interfacial enhanced breathable conductive hydrogel network (BCHN) and skin for high-fidelity long-term electrophysiological monitoring. By embedding sodium chloride-containing polyvinyl alcohol hydrogel into an oxidized electrospun 3D porous polylactic acid skeleton, a BCHN with embedded enhanced interface featuring dense ion transport pathways and multiple water molecule-adsorbing sites is constructed. Upon application, the breathable (1.85 kg·m⁻²·day⁻¹, ~3× skin perspiration) flexible conductive hydrogel network with bending stiffness of ~10−10N·m² seamlessly conforms to the microscopic landscape of the skin, forming a symbiotic BCHN-skin interface, which allows BCHN to “breathe” in harmony with the skin to preserve stable hydration and conductivity by dynamically balancing sweat capture, permeation, and evaporation, evidenced by a sustained 55 Ω impedance even at 20%RH. Integrated into a wearable monitoring system, the BCHN electrodes maintain high-quality signals (SNR > 25 dB) for over 30 days, thereby permitting the quantitative assessment and early warning of driver fatigue through long-term electroencephalography analysis.
AB - Wearable electrophysiological monitoring based on hydrogel electrodes is pivotal for decoding the body’s “electrical language”, yet fundamentally hampered by the unstable mechano-electrical interface between flexible electrodes and the skin caused by dehydration and poor breathability. Here, we demonstrate a symbiotic interface between an embedded-interfacial enhanced breathable conductive hydrogel network (BCHN) and skin for high-fidelity long-term electrophysiological monitoring. By embedding sodium chloride-containing polyvinyl alcohol hydrogel into an oxidized electrospun 3D porous polylactic acid skeleton, a BCHN with embedded enhanced interface featuring dense ion transport pathways and multiple water molecule-adsorbing sites is constructed. Upon application, the breathable (1.85 kg·m⁻²·day⁻¹, ~3× skin perspiration) flexible conductive hydrogel network with bending stiffness of ~10−10N·m² seamlessly conforms to the microscopic landscape of the skin, forming a symbiotic BCHN-skin interface, which allows BCHN to “breathe” in harmony with the skin to preserve stable hydration and conductivity by dynamically balancing sweat capture, permeation, and evaporation, evidenced by a sustained 55 Ω impedance even at 20%RH. Integrated into a wearable monitoring system, the BCHN electrodes maintain high-quality signals (SNR > 25 dB) for over 30 days, thereby permitting the quantitative assessment and early warning of driver fatigue through long-term electroencephalography analysis.
UR - https://www.scopus.com/pages/publications/105047594517
U2 - 10.1038/s41467-026-75372-3
DO - 10.1038/s41467-026-75372-3
M3 - 文章
C2 - 42431953
AN - SCOPUS:105047594517
SN - 2041-1723
VL - 17
JO - Nature Communications
JF - Nature Communications
IS - 1
M1 - 8528
ER -