TY - JOUR
T1 - A study of virtual resistor-based active damping alternatives for LCL resonance in grid-connected voltage source inverters
AU - Liu, Teng
AU - Liu, Jinjun
AU - Liu, Zeng
AU - Liu, Zipeng
N1 - Publisher Copyright:
© 1986-2012 IEEE.
PY - 2020/1
Y1 - 2020/1
N2 - LCL resonance complicates the design of a current control loop and can even threaten its stability. Extensive approaches have been proposed to deal with this resonance, among which active damping (AD) schemes based on the feedback of a single filter variable have been shown to be effective and cost-efficient. This paper presents a study of such AD techniques, where a generalized approach to developing an AD controller by relating a control diagram to an equivalent circuit is proposed. Based on this approach, AD controller forms with any one of four commonly used filter variables to realize virtual resistors (VRs) in six different connections to the LCL filter are derived. Comparisons are then made between these 24 AD controller alternatives by considering the implementation complexity of the AD controller, the number of measuring sensors, and the effect of the AD controller on the power stage. Consequently, grid-side current feedback AD to realize a VR in parallel with the filter capacitor is selected as a considered alternative. Next, two issues associated with the practical implementation of the selected grid-side current feedback AD, caused by the second-order differential expression and the digital time delay, are discussed and solved. Finally, the selected AD method is analyzed in the discrete z-domain, and its effectiveness is experimentally verified.
AB - LCL resonance complicates the design of a current control loop and can even threaten its stability. Extensive approaches have been proposed to deal with this resonance, among which active damping (AD) schemes based on the feedback of a single filter variable have been shown to be effective and cost-efficient. This paper presents a study of such AD techniques, where a generalized approach to developing an AD controller by relating a control diagram to an equivalent circuit is proposed. Based on this approach, AD controller forms with any one of four commonly used filter variables to realize virtual resistors (VRs) in six different connections to the LCL filter are derived. Comparisons are then made between these 24 AD controller alternatives by considering the implementation complexity of the AD controller, the number of measuring sensors, and the effect of the AD controller on the power stage. Consequently, grid-side current feedback AD to realize a VR in parallel with the filter capacitor is selected as a considered alternative. Next, two issues associated with the practical implementation of the selected grid-side current feedback AD, caused by the second-order differential expression and the digital time delay, are discussed and solved. Finally, the selected AD method is analyzed in the discrete z-domain, and its effectiveness is experimentally verified.
KW - Active damping (AD)
KW - LCL resonance
KW - virtual resistor (VR)
KW - voltage source inverters (VSIs)
UR - https://www.scopus.com/pages/publications/85074199693
U2 - 10.1109/TPEL.2019.2911163
DO - 10.1109/TPEL.2019.2911163
M3 - 文章
AN - SCOPUS:85074199693
SN - 0885-8993
VL - 35
SP - 247
EP - 262
JO - IEEE Transactions on Power Electronics
JF - IEEE Transactions on Power Electronics
IS - 1
M1 - 8691585