A randomised comparison of healing response between the BuMA Supreme stent and the XIENCE stent at one-month and two-month follow-up: PIONEER-II OCT randomised controlled trial

  • Taku Asano
  • , Qinhua Jin
  • , Yuki Katagiri
  • , Norihiro Kogame
  • , Kuniaki Takahashi
  • , Chun Chin Chang
  • , Ply Chichareon
  • , Chang Qian Wang
  • , Bei Shi
  • , Xi Su
  • , Guosheng Fu
  • , Yan Qing Wu
  • , Xu Chen Zhou
  • , Zuyi Yuan
  • , Joanna J. Wykrzykowska
  • , Jan J. Piek
  • , Patrick W. Serruys
  • , Yoshinobu Onuma
  • , Yun Dai Chen
  • Academic Medical Center

科研成果: 期刊稿件 › 文章 › 同行评审

16 引用 (Scopus)

摘要

AIMS: The aim of this study was to compare the strut coverage of the XIENCE stent with that of the BuMA Supreme sirolimus-eluting cobalt-chromium stent, which has a shorter drug elution, on optical coherence tomography (OCT) one or two months after implantation. METHODS AND RESULTS: The PIONEER-II OCT trial was a multicentre, two-arm randomised trial, which comprised two cohorts: cohort-1 underwent an OCT imaging one month after coronary intervention (BuMA: 16 patients with 18 lesions, XIENCE: 15 patients with 17 lesions), whereas cohort-2 underwent OCT at two months (BuMA: 21 patients with 21 lesions, XIENCE: 23 patients with 28 lesions). The primary hypotheses were non-inferiority of the BuMA stent to the XIENCE stent in percent strut coverage at one month (cohort-1) or two months (cohort-2). In cohort-1, the BuMA stent was non-inferior to the XIENCE stent in terms of the strut coverage (83.8±10.4% for BuMA vs. 73.0±17.5% for XIENCE, pfor noninferiority <0.001), and was also significantly higher than the XIENCE (pfor superiority 0.037). In cohort-2, the BuMA stent was non-inferior to the XIENCE stent in OCT strut coverage (80.3±18.3% vs. 73.3±21.3%, pfor noninferiority 0.006, pfor superiority 0.24). Healing scores showed better healing in the BuMA stent in cohort-1 (32.36±21.59 vs. 54.88±34.65, p=0.027), whereas there was comparable healing between the BuMA and XIENCE stents in cohort-2 (39.86±37.77 vs. 53.75±42.84, p=0.25). CONCLUSIONS: The BuMA Supreme had a faster coverage than the XIENCE at one month, presumably due to faster and shorter sirolimus elution. The difference in tissue coverage became less evident at two months.

源语言英语
页(从-至)e1306-e1315
期刊EuroIntervention
卷14
期12
DOI
出版状态已出版 - 20 12月 2018