T1 - A novel principle of directional relay for wind power integration based on model recognition in time-domain
AU - Chenqing, Wang
AU - Guobing, Song
AU - Jinhua, Zhang
N1 - Publisher Copyright:
© 2016 IEEE.
PY - 2016/12/9
Y1 - 2016/12/9
N2 - The fault characteristics of wind power system which are reflected in the weak feed features, variation of system impedance, frequency deviation, and non-sinusoidal waveform, will cause the inadaptation of traditional directional relay to wind power integration system. To solve this problem, a new directional relay suitable for wind power system is proposed in this paper. The models of forward and backward fault in time domain on full fault component are firstly built. The fault current and voltage in the fault loop satisfy the positive R-L model when a forward fault occurs, while satisfy the negative R-L model when a backward fault occurs. Then waveform correlation in time domain is adopted to recognize the positive and negative R-L model. When the correlation coefficient is larger than 0, the fault is a forward fault, otherwise the fault is a backward fault. Thus the novel directional relay criterion is formed accordingly. To avoid voltage dead zone, the memory voltage waveform is utilized when the fault voltage is near 0 in the proposed scheme. Finally the proposed directional relay scheme is verified by the PSCAD based simulation results and field fault recording data of wind power integration system.
AB - The fault characteristics of wind power system which are reflected in the weak feed features, variation of system impedance, frequency deviation, and non-sinusoidal waveform, will cause the inadaptation of traditional directional relay to wind power integration system. To solve this problem, a new directional relay suitable for wind power system is proposed in this paper. The models of forward and backward fault in time domain on full fault component are firstly built. The fault current and voltage in the fault loop satisfy the positive R-L model when a forward fault occurs, while satisfy the negative R-L model when a backward fault occurs. Then waveform correlation in time domain is adopted to recognize the positive and negative R-L model. When the correlation coefficient is larger than 0, the fault is a forward fault, otherwise the fault is a backward fault. Thus the novel directional relay criterion is formed accordingly. To avoid voltage dead zone, the memory voltage waveform is utilized when the fault voltage is near 0 in the proposed scheme. Finally the proposed directional relay scheme is verified by the PSCAD based simulation results and field fault recording data of wind power integration system.
KW - directional relay
KW - field fault recording data
KW - model recognition
KW - waveform correlation
KW - wind power integration
UR - https://www.scopus.com/pages/publications/85010007300
U2 - 10.1109/APPEEC.2016.7779809
DO - 10.1109/APPEEC.2016.7779809
M3 - 会议稿件
AN - SCOPUS:85010007300
T3 - Asia-Pacific Power and Energy Engineering Conference, APPEEC
SP - 1851
EP - 1855
BT - IEEE PES APPEEC 2016 - 2016 IEEE PES Asia Pacific Power and Energy Engineering Conference
PB - IEEE Computer Society
T2 - 2016 IEEE PES Asia Pacific Power and Energy Engineering Conference, APPEEC 2016
Y2 - 25 October 2016 through 28 October 2016
ER -