TY - JOUR
T1 - A high sensitivity capacitive micromachined ultrasonic transducer (CMUT) with stepped cavity structure
AU - Jia, Haoliang
AU - Zhang, Wangyang
AU - Liu, Tao
AU - Ren, Lei
AU - Qin, Shaohui
AU - Yuan, Jiawei
AU - Zhao, Libo
AU - Li, Zhikang
AU - Mu, Xiaojing
N1 - Publisher Copyright:
© 2025
PY - 2025/8/1
Y1 - 2025/8/1
N2 - Compared to traditional piezoelectric transducers, capacitive micromachined ultrasonic transducers (CMUTs) offer advantages such as wide bandwidth, low power consumption, small size, and better impedance matching with fluids, enabling more applications in a wide range of temperature and humidity. This paper investigates the design, simulation, fabrication, and experimental validation of a CMUT with a stepped cavity structure. Finite element analysis (FEA) was used to optimize electrode size, cavity height, and cavity radius, establishing an optimal structure 2-stage-Optimal, whose electromechanical coupling coefficients are superior to conventional structures. A 16 × 16 element CMUTs array with 2-stage-Optimal structure was fabricated, and the electrical impedance characteristics and resonance frequency of the fabricated CMUTs chip were measured. Simple impedance matching was performed to optimize its transmission efficiency. Under a DC bias voltage of 80 % collapse voltage, the CMUTs chip's center frequency is approximately 0.9 MHz, with a −6 dB bandwidth of about 82.6 %, a maximum transmission sensitivity of 4.3 kPa/V, and a maximum reception sensitivity of 101.5 mV/kPa, or −199.8 dB (ref. 1 V/μPa). The study shows that the 2-stage-Optimal stepped cavity structure CMUT exhibit high sensitivity characteristics.
AB - Compared to traditional piezoelectric transducers, capacitive micromachined ultrasonic transducers (CMUTs) offer advantages such as wide bandwidth, low power consumption, small size, and better impedance matching with fluids, enabling more applications in a wide range of temperature and humidity. This paper investigates the design, simulation, fabrication, and experimental validation of a CMUT with a stepped cavity structure. Finite element analysis (FEA) was used to optimize electrode size, cavity height, and cavity radius, establishing an optimal structure 2-stage-Optimal, whose electromechanical coupling coefficients are superior to conventional structures. A 16 × 16 element CMUTs array with 2-stage-Optimal structure was fabricated, and the electrical impedance characteristics and resonance frequency of the fabricated CMUTs chip were measured. Simple impedance matching was performed to optimize its transmission efficiency. Under a DC bias voltage of 80 % collapse voltage, the CMUTs chip's center frequency is approximately 0.9 MHz, with a −6 dB bandwidth of about 82.6 %, a maximum transmission sensitivity of 4.3 kPa/V, and a maximum reception sensitivity of 101.5 mV/kPa, or −199.8 dB (ref. 1 V/μPa). The study shows that the 2-stage-Optimal stepped cavity structure CMUT exhibit high sensitivity characteristics.
KW - CMUT
KW - Electromechanical coupling coefficient
KW - Stepped cavity
KW - Ultrasonic sensitivity
UR - https://www.scopus.com/pages/publications/105001841053
U2 - 10.1016/j.sna.2025.116519
DO - 10.1016/j.sna.2025.116519
M3 - 文章
AN - SCOPUS:105001841053
SN - 0924-4247
VL - 389
JO - Sensors and Actuators A: Physical
JF - Sensors and Actuators A: Physical
M1 - 116519
ER -