跳到主要导航 跳到搜索 跳到主要内容

A data analysis method for detecting wall thermal resistance considering wind velocity in situ

  • Zhengzhou Branch of China Nuclear Power Engineering Co Ltd.
  • Xi'an Jiaotong University

科研成果: 期刊稿件 › 文章 › 同行评审

25 引用 (Scopus)

摘要

To improve the accuracy of data analysis methods for the field measurement of wall thermal resistance, a method considering wind velocity is presented through an analysis of both surface heat flux and temperature samples. This analysis method takes the wall heat transfer of linear system into account, simplifying the first order differential equation of wall transient response based on the nodes of the interior and exterior wall surfaces. An approximate solution has been proposed in the form of time domain interpolation. By applying the weighted residual method for the approximate solution, the data analysis method about temperature, heat flux, and wind velocity can be achieved. A transient heat transfer model of a wall was established applying the infinite difference method, by which the proposed analysis method was validated in this paper. Additionally, the heat flow meter experiment platform considering wind velocity was built, on which the proposed method, the mean method and the dynamic analysis method suggested by the international standard ISO 9869 were applied to the test wall under different wind velocities. The wall thermal resistance value obtained in our proposed method has proven to be in better agreement with that obtained for a steady state.

源语言英语
页(从-至)1647-1653
页数7
期刊Energy and Buildings
卷42
期10
DOI
出版状态已出版 - 10月 2010

学术指纹

探究 'A data analysis method for detecting wall thermal resistance considering wind velocity in situ' 的科研主题。它们共同构成独一无二的学术指纹。

引用此