TY - JOUR
T1 - A Current Stress Reduction Method for Modular Magnetic-Coupled Converter (MMCC) in Medium-Voltage Motor Drives
AU - Song, Qunsheng
AU - Du, Sixing
AU - Liu, Jinjun
AU - Wang, Zhan
N1 - Publisher Copyright:
© 1986-2012 IEEE.
PY - 2025
Y1 - 2025
N2 - The modular magnetic-coupled converter (MMCC) greatly reduces the volume of the transformers and dc capacitors in medium-voltage motor drives. It consists of numerous power modules, each of which integrates several H-bridges and an intermediate DC-DC stage. The DC-DC stage utilizes six half-bridges jointly connected to the multi-winding high-frequency transformer via LC resonant tanks. This structure provides the hardware channel for the fluctuating power spontaneous cancellation. However, this feature leads to high current stress issues in the DC-DC stage. To address this problem, this article proposes a novel current stress reduction method for MMCC. It utilizes the converter apparent power to regulate the grid-side half-bridges in the DC-DC stage for proper power transmission. Meanwhile, the grid-side channel impedances in the DC-DC stage are intentionally designed to differ from the original ones. The double-line-frequency power fluctuations from the grid-side H-bridges are barely transferred to the DC-DC stage, whereas those from the motor-side H-bridges still cancel each other out in the multi-winding transformer. Compared to the conventional MMCC, the proposed software method reduces the current stress of the grid-side half-bridges by more than 47%. Moreover, the total switching device cost is lowered by 25%, and the converter cost is reduced by more than 15%. The feasibility of the proposal is verified by simulations and experiments.
AB - The modular magnetic-coupled converter (MMCC) greatly reduces the volume of the transformers and dc capacitors in medium-voltage motor drives. It consists of numerous power modules, each of which integrates several H-bridges and an intermediate DC-DC stage. The DC-DC stage utilizes six half-bridges jointly connected to the multi-winding high-frequency transformer via LC resonant tanks. This structure provides the hardware channel for the fluctuating power spontaneous cancellation. However, this feature leads to high current stress issues in the DC-DC stage. To address this problem, this article proposes a novel current stress reduction method for MMCC. It utilizes the converter apparent power to regulate the grid-side half-bridges in the DC-DC stage for proper power transmission. Meanwhile, the grid-side channel impedances in the DC-DC stage are intentionally designed to differ from the original ones. The double-line-frequency power fluctuations from the grid-side H-bridges are barely transferred to the DC-DC stage, whereas those from the motor-side H-bridges still cancel each other out in the multi-winding transformer. Compared to the conventional MMCC, the proposed software method reduces the current stress of the grid-side half-bridges by more than 47%. Moreover, the total switching device cost is lowered by 25%, and the converter cost is reduced by more than 15%. The feasibility of the proposal is verified by simulations and experiments.
KW - current stress
KW - high-frequency transformer
KW - multilevel converter
KW - resonant converter
KW - variable-speed drives
UR - https://www.scopus.com/pages/publications/105025775266
U2 - 10.1109/TPEL.2025.3644345
DO - 10.1109/TPEL.2025.3644345
M3 - 文章
AN - SCOPUS:105025775266
SN - 0885-8993
JO - IEEE Transactions on Power Electronics
JF - IEEE Transactions on Power Electronics
ER -