跳到主要导航 跳到搜索 跳到主要内容

A comparison study of sinogram- and image-domain penalized re-weighted least-squares approaches to noise reduction for low-dose cone-beam CT

  • Hao Zhang
  • , Yan Liu
  • , Hao Han
  • , Jing Wang
  • , Jianhua Ma
  • , Lihong Li
  • , Zhengrong Liang
  • Stony Brook University
  • University of Texas Southwestern Medical Center
  • Southern Medical University
  • City University of New York

科研成果: 书/报告/会议事项章节会议稿件同行评审

4 引用 (Scopus)

摘要

Reducing X-ray exposure to the patients is one of the major research efforts in the computed tomography (CT) field, and one of the common strategies to achieve it is to lower the mAs setting (by lowering the X-ray tube current and/or shortening the exposure time) in currently available CT scanners. However, the image quality from low mAs acquisition is severely degraded due to excessive quantum noise, if no adequate noise control is applied during image reconstruction. Different from filter-based algorithms, statistical reconstruction algorithms model the statistical property of the noise using a cost function and minimize the cost function for an optimal solution in statistical sense. The algorithms have shown to be feasible and effective in both sinogram and image domain. In our previous researches, we proposed penalized reweighted least-squares (PRWLS) approaches to sinogram noise reduction and image reconstruction for low-dose CT imaging, which are in this statistical category. This work is a continuation of the research along this direction and aims to compare the reconstruction quality of two different PRWLS implementations for low-dose cone-beam CT reconstruction: (1) PRWLS sinogram restoration followed by analytical Feldkamp-Davis- Kress reconstruction, (2) fully iterative PRWLS image reconstruction. Inspired by our recent study on the variance of low-mAs projection data in presence of electric noise background, a more accurate weight was adopted in the weighted least-squares term. An anisotropic quadratic form penalty was utilized in both PRWLS implementations to preserve edges during noise reduction. Experiments using the CatPhan® 600 phantom and anthropomorphic head phantom were carried to study the relevant performance of these two implementations on image reconstruction. The results revealed that the implementation (2) can outperform implementation (1) in terms of noise-resolution tradeoff measurement and analysis of the reconstructed small objects due to its matched image edge-preserved penalty in the image domain. However, those gains are offset by the cost of increased computational time. Thus, further examination of real patient data is necessary to show the clinical significance of the iterative PRWLS image reconstruction over the PRWLS sinogram restoration.

源语言英语
主期刊名Medical Imaging 2013
主期刊副标题Physics of Medical Imaging
DOI
出版状态已出版 - 2013
已对外发布
活动Medical Imaging 2013: Physics of Medical Imaging - Lake Buena Vista, FL, 美国
期限: 11 2月 201314 2月 2013

出版系列

姓名Progress in Biomedical Optics and Imaging - Proceedings of SPIE
8668
ISSN(印刷版)1605-7422

会议

会议Medical Imaging 2013: Physics of Medical Imaging
国家/地区美国
Lake Buena Vista, FL
时期11/02/1314/02/13

学术指纹

探究 'A comparison study of sinogram- and image-domain penalized re-weighted least-squares approaches to noise reduction for low-dose cone-beam CT' 的科研主题。它们共同构成独一无二的指纹。

引用此