TY - JOUR
T1 - A 0.0075 mm2, 0.0139 FoM Double-Ring Vernier TDC with Vernier Arbiter Phase Calibration and Code Error Cancellation for 26 dB SFDR Improvement in ToF-PET
AU - Wang, Han
AU - Xin, Youze
AU - Xie, Yiyun
AU - Hu, Pengfei
AU - Chen, Hongxu
AU - Xu, Ziyang
AU - Wang, Xuhu
AU - Hu, Congzhen
AU - Wang, Chi
AU - Li, Lu
AU - Fang, Lei
AU - Geng, Li
AU - Zhang, Bing
N1 - Publisher Copyright:
© 2007-2012 IEEE.
PY - 2026
Y1 - 2026
N2 - This work presents a PET-oriented double-ring Vernier time-to-digital converter (DRVTDC) that targets the timing-quantization block required in multi-voltage-threshold (MVT) and time-over-threshold (ToT) front-end readout for time-of-flight (ToF) positron emission tomography (PET) applications. This work addresses two critical error mechanisms that limit the use of multi-stage Vernier TDCs: parallel output misalignment (POM) between quantization stages and mismatch-induced chasing error (MCE) in the Vernier arbiter array. To suppress these errors, a joint calibration scheme combining code error cancellation (CEC) and Vernier arbiter phase calibration (VAPC) is proposed. The core TDC achieves a 10.4-ps resolution with only 0.0075 mm2 core area. The implemented 7-bit coarse counter provides a dynamic range (DR) of 5.12 μs. Empowered by these techniques, the measured DNL and INL ranges are significantly improved from +3.17/−0.89 LSB and +7.0/−6.9 LSB to +0.34/−0.29 LSB and +1.15/−1.09 LSB, respectively, alongside a 26-dB enhancement in the SFDR. The core TDC consumes 1.758 mW, with a total of 5.526 mW including the PLLs.
AB - This work presents a PET-oriented double-ring Vernier time-to-digital converter (DRVTDC) that targets the timing-quantization block required in multi-voltage-threshold (MVT) and time-over-threshold (ToT) front-end readout for time-of-flight (ToF) positron emission tomography (PET) applications. This work addresses two critical error mechanisms that limit the use of multi-stage Vernier TDCs: parallel output misalignment (POM) between quantization stages and mismatch-induced chasing error (MCE) in the Vernier arbiter array. To suppress these errors, a joint calibration scheme combining code error cancellation (CEC) and Vernier arbiter phase calibration (VAPC) is proposed. The core TDC achieves a 10.4-ps resolution with only 0.0075 mm2 core area. The implemented 7-bit coarse counter provides a dynamic range (DR) of 5.12 μs. Empowered by these techniques, the measured DNL and INL ranges are significantly improved from +3.17/−0.89 LSB and +7.0/−6.9 LSB to +0.34/−0.29 LSB and +1.15/−1.09 LSB, respectively, alongside a 26-dB enhancement in the SFDR. The core TDC consumes 1.758 mW, with a total of 5.526 mW including the PLLs.
KW - code error cancellation (CEC)
KW - double-ring Vernier
KW - mismatch-induced chasing error (MCE)
KW - parallel output misalignment (POM)
KW - Positron emission tomography (PET)
KW - time-to-digital converter (TDC)
KW - Vernier arbiter phase calibration (VAPC)
UR - https://www.scopus.com/pages/publications/105044956283
U2 - 10.1109/TBCAS.2026.3712740
DO - 10.1109/TBCAS.2026.3712740
M3 - 文章
AN - SCOPUS:105044956283
SN - 1932-4545
JO - IEEE Transactions on Biomedical Circuits and Systems
JF - IEEE Transactions on Biomedical Circuits and Systems
ER -