TY - JOUR
T1 - 3D-printed PEEK implant for mandibular defects repair - a new method
AU - Kang, Jianfeng
AU - Zhang, Jie
AU - Zheng, Jibao
AU - Wang, Ling
AU - Li, Dichen
AU - Liu, Shuguang
N1 - Publisher Copyright:
© 2021 Elsevier Ltd
PY - 2021/4
Y1 - 2021/4
N2 - Functional reconstruction of large-size mandibular continuity defect is still a major challenge in the oral and maxillofacial surgery due to the unsatisfactory repair effects and various complications. This study aimed to develop a new functional repair method for mandibular defects combined with 3D-printed polyetheretherketone (PEEK) implant and the free vascularized fibula graft, and evaluated the service performance of the implant under whole masticatory motion. The design criteria and workflows of the mandibular reconstruction were established based on the requirements of safety, functionality, and shape consistency. Both the biomechanical behavior and the mechanobiological property of mandibular reconstruction under various masticatory motion were investigated by the finite element analysis. The maximum von Mises stress of each component was lower than the yield strength of the corresponding material and the safety factor was more than 2.3 times, which indicated the security of the repair method can be guaranteed. Moreover, the actual deformation of the reconstruction model was lower than that of the normal mandible under most clenching tasks, which assured the primary stability. More than 80% of the volume elements in the bone graft can obtain effective mechanical stimulation, which benefited to reduce the risks of bone resorption. Finally, the novel repair method was applied in clinic and good clinical performances have been achieved. Compared with the conventional fibular bone graft for surgical mandibular reconstruction, this study provides excellent safety and stability to accomplish the functional reconstruction and aesthetic restoration of the mandible defect.
AB - Functional reconstruction of large-size mandibular continuity defect is still a major challenge in the oral and maxillofacial surgery due to the unsatisfactory repair effects and various complications. This study aimed to develop a new functional repair method for mandibular defects combined with 3D-printed polyetheretherketone (PEEK) implant and the free vascularized fibula graft, and evaluated the service performance of the implant under whole masticatory motion. The design criteria and workflows of the mandibular reconstruction were established based on the requirements of safety, functionality, and shape consistency. Both the biomechanical behavior and the mechanobiological property of mandibular reconstruction under various masticatory motion were investigated by the finite element analysis. The maximum von Mises stress of each component was lower than the yield strength of the corresponding material and the safety factor was more than 2.3 times, which indicated the security of the repair method can be guaranteed. Moreover, the actual deformation of the reconstruction model was lower than that of the normal mandible under most clenching tasks, which assured the primary stability. More than 80% of the volume elements in the bone graft can obtain effective mechanical stimulation, which benefited to reduce the risks of bone resorption. Finally, the novel repair method was applied in clinic and good clinical performances have been achieved. Compared with the conventional fibular bone graft for surgical mandibular reconstruction, this study provides excellent safety and stability to accomplish the functional reconstruction and aesthetic restoration of the mandible defect.
KW - 3D printing
KW - Biomechanical analysis
KW - Customized design
KW - Mandibular defects reconstruction
KW - Polyether ether ketone (PEEK)
UR - https://www.scopus.com/pages/publications/85099863788
U2 - 10.1016/j.jmbbm.2021.104335
DO - 10.1016/j.jmbbm.2021.104335
M3 - 文章
C2 - 33494021
AN - SCOPUS:85099863788
SN - 1751-6161
VL - 116
JO - Journal of the Mechanical Behavior of Biomedical Materials
JF - Journal of the Mechanical Behavior of Biomedical Materials
M1 - 104335
ER -